4.5 Troubleshooting

Failure
Insufficient gas flow
Assembly impossible
Gas issues from the
valve
Icing
Cause
Valve closed or insufficiently open
Cylinder empty or not sufficiently full
Non-operational valve
Non-operational pressure regulator
Non-operational downstream
equipment
Non-compatible adapters
Damaged adapters
Leak from seat disk holder of pressure
regulator
Excessively low operating
temperature
Excessive flow-rate
REDLINE® C 300 cylinder regulators
Remedy
Open the cylinder valve
Change the cylinder
Change the cylinder
Call Linde
Replace the equipment
Check the compatibility between the
gas and the pressure regulator
Call Linde
Close the cylinder valve – call Linde
Close the cylinder valve – bring the
unit back to ambient temperature
Return to utilisation at nominal
flow-rate
09