Download Print this page

Linde REDLINE C 300 Instruction Manual page 6

Cylinder regulators

Advertisement

06
REDLINE® C 300 cylinder regulators
3.2 Safety components
Connectable safety valve is an option.
Note: This HP pressure regulator must be used with a safety component on the medium pressure
system, in order to avoid risks of overpressure.
3.3 Designation of indications (depending on model)
Barred oil can (ISO 7000)
bars
psig
Max Inlet P
Q
P2 max
N₂
« mm-yy »
XYZ
- → +
Num:
or LP
MP
 
or HP
3.4 Operational specifications (depending on model)
Maximum supply pressure
Sealing
Operating temperature
Normal operating conditions
i (Coefficient of irregularity)
R (Coefficient of pressure increase)
Outlet pressure
Do not oil – do not grease
Pressure (1 bar = 100 kPa)
Pressure (1 psig = 6.9 kPa)
Maximum inlet pressure
Nominal flow-rate (in m3/h)
Maximum outlet pressure
Nitrogen
Month – year of manufacture
Month and year coded
Direction of increasing pressure
Serial number
Low pressure gate
Medium pressure gate
High pressure gate
Safety valve
300 bar: working pressure stamped on the body
–8
leak rate ≤ 10
mbar l/s He
from –20 °C to +60 °C
1.013 bar at 23 °C
C 300/1 ≤ 20 % according to ISO 2503
C300/2 ≤ 15% according to ISO 2503
C 300/1 ≤ 20 % according to ISO 2503
C300/2 ≤ 15% according to ISO 2503
1, 3, 8,16 or 35 bar for C 300/2 and 35 or 50 bar for C 300/1

Advertisement