Download Print this page

Settings - Jaga BRIZA 12-JFCC Manual

Fancoil controller

Advertisement

Available languages

Available languages

1. 
2.  SETTINGS
2.1.  ADJUSTING THE WATER TEMPERATURE
2.1.1.  Adjusting the maximum water temperature for cooling
By reducing the water temperature setting, the unit will start later. If the water tempe-
rature is set higher, the unit will start sooner .
1. Start setup mode: press and hold the [-] button until the blue LED flashes 5x and release .
2. Short press the [-] or [+] button to adjust the set temperature .
RS485 A/B
I2C
PC / RF
CO2
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
CONTROL PANEL
Tsens 2
THERMOSTATE 1
Tsens 3
ON
Tsens 4
N L
GND 0-10V 24V
1
2
3
4
5
6
7
8
GND
24V
DIPSWITCH
JAGA
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
GND
0-10V
V.H.
GND
0-10V
V.C.
Automatic control: The green LED lights up when the water temperature (supply water) is lower than the
set temperature
3. Exit setup mode: hold the [-] button until the blue LED flashes 5x and release .
2.1.2.  Adjusting the minimum water temperature for heating
By increasing the water temperature setting, the unit will start later. If the water temperature is set lower, the unit will
start sooner .
In combination with a heat pump, it may be necessary to reduce the water temperature .
1. Start setup mode: Press and hold the [+] button until the red LED flashes 5x and release .
2. Short press the [-] or [+] button to adjust the set temperature .
RS485 A/B
I2C
PC / RF
CO2
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
CONTROL PANEL
Tsens 2
THERMOSTATE 1
Tsens 3
ON
Tsens 4
N L
GND 0-10V 24V
1
2
3
4
5
6
7
8
GND
24V
DIPSWITCH
JAGA
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
GND
0-10V
V.H.
GND
0-10V
V.C.
Automatic control: The green LED lights when the water temperature (supply water) exceeds the set
temperature .
3. Exit setup mode: press and hold the [+] button until the red LED flashes 5x and release .
After 30 seconds, the new settings are automatically saved and the device returns to the selected mode.
JAGA NV | BRIZA 12 - JFCC | MANUEL | 2023.03.06 | V.5.2
12 ̊ C
14 ̊ C
16 ̊ C
18 ̊ C
The blue LED flashes quickly when the minimum temperature is reached.
The red LED flashes quickly
when the maximum temperature is reached. .
24 ̊ C
26 ̊ C
28 ̊ C
30 ̊ C
The blue LED flashes quickly when the minimum temperature is reached.
The red LED flashes quickly
when the maximum temperature is reached. .
20 ̊ C
22 ̊ C
24 ̊ C
26 ̊ C
32 ̊ C
34 ̊ C
36 ̊ C
38 ̊ C
RS485 A/B
I2C
PC / RF
CO2
.
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
Tsens 2
Tsens 3
ON
Tsens 4
N L
GND 0-10V 24V
1
2
3
4
GND
24V
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
GND
0-10V
V.H.
GND
0-10V
V.C.
RS485 A/B
I2C
PC / RF
CO2
.
POWER 45W
INPUT: 110-240VAC
OUTPUT: 24V
Tsens 1
Tsens 2
Tsens 3
ON
Tsens 4
N L
GND 0-10V 24V
1
2
3
4
GND
24V
GND
24V
GND
NTC1
GND
0-10V +24V
+24V
RC
GND
IN/OUT
GND
0-10V
V.H.
GND
0-10V
V.C.
51
EN

Advertisement

loading