• Spot and pause time (Spot).
This function is blocked when function 3L is activated. If we select spot ON time, the Spot Time function
appears on the display screen. If we select this, we can adjust it from 0.3 to 25 seconds by means of the
adjustment bar. Besides this function, the display screen also shows Pause Time. When this is selected, use
the adjustment bar to regulate the pause time between one welding spot or section and another. The pause
time varies between 0 (OFF) and 5 seconds.
To access the Spot Time and Pause Time functions, press the knob B for less than 2 seconds. Adjustment
is always made by means of the knob B. To confirm, simply press it for less than 2 seconds. Once the choice
has been confirmed, return is always made to the screen (PROCESS PARAMS).
• HSA (Automatic Hot Start).
This function is blocked when function 3L is activated. Once the function has been enabled, the operator can
adjust the starting current (Start Curr) from 10 to 200% of the welding current (Default 130%). The duration of
this current (S�C� Time) may be adjusted from 0.1 to 10 seconds (default 0.5 sec.). The switching time (Slope
Time) between the starting current (Start Curr) and the welding current may also be adjusted from 0.1 to 10
seconds (default 0.5 seconds).
• CRA (crater filler - final crater filling).
This function is blocked when function 3L is activated. It operates in welding mode 2T, 4T and also in combi-
nation with function HSA.
After activating the function, the operator may adjust the connection time (Slope Time) between the welding
current and the crater filling current (Crater Curr�) from 0.1 to 10 seconds (default 0.5 seconds).
The operator can also adjust the crater filling current (Crater Curr.) from 10 to 200% of the welding current
(Default 60%).
The time (C�C� Time) of the crater filling current duration may be adjusted from 0.1 to 10 seconds (default 0.5
seconds).