Radio communication
Frequency range
Maximum transmission power
Range
Protocol
MAC protocol
Zigbee channels
Functional data of sensor
Humidity sensor
Range of use
Measuring range
Measuring accuracy at
30...70 % r.h.
0...30 % r.h./70...100 % r.h.
Time constant t
Output signal
Temperature sensor
Range of use
Measuring range
Measuring accuracy at
21...25 ° C
15...21 °C/25...35 ° C,
0...15 °C/35...50 ° C
Time constant t
Output signal
CO
2
Range of use
Measuring range
Measuring accuracy at
0...2000 ppm
Time constant t
Output signal
Siemens
Smart Infrastructure
63
63
sensor
63
2400...2483.5 MHz
7.73 dBm
≤ 10 m, depending on application and
building
Open Thread
IEEE 802.15.4
11...26
0...100 % r.h. (non-condensing)
0...100 % r.h.
± 2 % r.h.
± 5 % r.h.
20 s
Wireless digital signal (0...10000)
-15...+50 ° C
0...50 ° C
± 0.3 K
± 0.7 K
± 1 K
≤ 8.5 min (depending on air movement and
thermal coupling to the wall)
Wireless digital signal (0...10000)
0...5000 ppm
0...5000 ppm
± 50 ppm / ± 2 % m.v.
5 min
Wireless digital signal (0...10000)