Electrical Parameters - Mains MV4k/1 Instructions Manual

Checkout controller
Table of Contents

Advertisement

Electrical parameters of version 230V/50Hz
Power supplye:
Max. total power consumption:
Output current of the main belt:
Output current of the additional belt:
Max. Power consumption of an additional circuit L1:
Max. Power consumption of an additional circuit L2:
Power consumption of the control system:
Max. Motor power 1:
Max. Motor power 2:
Fuse:
glass fuse type F (fast)
short circuit limit current
Dimensions:
Electrical parameters of version 115V/60Hz
Power supply:
Max. total power consumption:
Output current of the main belt:
Output current of the additional belt:
Max. Power consumption of an additional circuit L1:
Max. Power consumption of an additional circuit L2:
Power consumption of the control system:
Max. Motor power 1:
Max. Motor power 2:
Fuse:
glass fuse type F (fast):
short circuit limit current:
Dimensions:
Working conditions:
Operating teperature:
Operating humidity (non-condensing):
Max. Workload:
Storage conditions:
Storage temperature:
Short storage temperature (to 24h):
Relative humidity (non-condensing):
Dimensions:
Width:
Hight:
Lenght:
Weight
Photocell:
Type:
Wavelenght:
Optimum range:
The tollerance of parallel movement of photocells axis:
The tollerance of perpendicular deviation
from photocells axis:
Standard cable lenght:
Connector:
MAINS S.C. E.M.Wosińscy Brzeziny 95-060 ul. Słowackiego 12, tel/fax: 48 46 8752 777 www.mains.pl; mains@mains.pl
230V/50Hz
700W
max 1 A
max 1 A
100W
100W
2,5W
200W
200W
4A/250V
40A
5x20 mm
115V/60Hz
700W
max 2 A
max 2 A
100W
100W
2,5W
200W
200W
8A/125V
80A
5x20 mm
0ºC~+40ºC
10% ~80%
1000m n.p.m.
-25ºC~+55ºC
+70ºC
10% ~80%
160mm
50mm
190mm
0,4kg
IR
940nm
700mm
50mm
< 3 degrees
2200mm
N2 blok
Parameters
controller: Mv4k
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mv4k/2

Table of Contents