Mains MV4k/1 Instructions Manual page 16

Checkout controller
Table of Contents

Advertisement

Controller MV4K - programing functions
Programming the opering modes MV4
Service mode 3 and 4
Service mode 3
Reset of the capacitor operating time
Service mode 4
Operating time the second belt (CTRL)
MAINS S.C. E.M.Wosińscy Brzeziny 95-060 ul. Słowackiego 12, tel/fax: 48 46 8752 777 www.mains.pl; mains@mains.pl
Service mode 3 is switched on while being in the service mode 2
by pressing the button [2] for about 3 seconds.
OUT diode should light up.
In the service mode 3 is possibility to reset the capacitor operating time
by pressing buttons [1] and [3] in the same time for about 5 seconds.
After it controller moves to the next mode for two motors.
(The capacitor operating time is about 10000 hours)
Service mode 4 is switched on while being in the service mode 3
by pressing the button [2] for about 3 seconds.
CTRL diode should light up.
In the service mode 4 is possibility to extend the operating time of the second
belt by pressing the button [1].
The first pressing the button extends the time for 1 s. the red diode lights.
The second pressing the button extends the time for 2 s. the green diode lights.
The third pressing the button extends the time for 3 s. the blue diode lights.
The fourth pressing the button moves to standard operating time,
none of diode lights.
Programming functions
SERVICE
S. START
2
OUT
CTRL
SERVICE
SERVICE
S. START
S. START
2
2
OUT
OUT
CTRL
CTRL
SERVICE
S. START
2
OUT
CTRL
SERVICE
S. START
2
OUT
CTRL
controller: Mv4k
16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mv4k/2

Table of Contents