After selection of a cooking procedure and OK, you must set – time – or core temperature.
1. Input time
Menu
Save
back
Four-figure time display from 00:00 to 23:59.
1. Time:
2. Core Temperature Core temperature range from 0° C to 99° C.
3. Use the direction arrows
and the Climatic Cursor for Temperature/Humidity.
3.2
Manual operation – Input of one step
Input parameters, "temperature/humidity" and "time" or "core temperature" and
start the Genius.
If desired, you can activate the preheating by pressing the key PreHeat see Sec. 8.
The Climatic Monitor indicates data of the advancing program.
Manual operation
with time setting
Manual
Change
Steam
Step
There are yellow bars in the input fields indicating the current state of the program.
Time: Bar is getting shorter to the left, time is running down.
Core temperature: Bar is getting longer to the right until the desired core temperature is reached.
Man. Steam: An additional manual humidification is always possible as long the key "Man. Steam"
is pressed.
A sound signal announces the end of the program.
bed_791318_gt_2v4_en
2. Input core temperature
Next
Preheat
Step
OFF
Basic setting is 00:00 move arrow
Time setting is 23:59 move arrow
Setting is move arrow
Setting is move arrow
and
to change between the input fields for time, core temperature
LED START is lit.
Remaining
time
Set time
Next
Step
Menu
Next
Preheat
Save
back
Step
OFF
to get to = continuous operation.
and you get again = continuous op.
and you get to 23:59
and you get to 00:00
Manual operation
with core temperature
Manual
Change
Steam
10
3.Input lines
Menu
Save
back
Set temperature and
humidity
Actual core
temperature
Set core
Next
temperature
Step
Step
Next
Prehea
Step
OFF
Need help?