XT2–13BEL
DETERGENT START SIGNAL
(230Vac - max 2A)
XT2–13AB
XT2–14BEL
RINSE AID START SIGNAL (230Vac
- max 2A)
XT2–14AB
XT2–15 [L1]
EXTERNAL DISPENSER POWER
SUPPLY (230Vac - max 5A)
XT2–16 [N]
E.17.1 Liquid detergent dispenser
• Connect the dispenser between terminals XT2–13BEL and
XT2–13AB.
XT2 - 13AB
XT2 - 13BEL
E.17.2 Rinse aid dispenser
• Connect the rinse aid dispenser between terminals XT2–
14BEL and XT2–14AB.
XT2 - 14AB
XT2 - 14BEL
E.17.3 Solid detergent dispenser
• Connect the dispenser between terminals XT2–15 [L1] and
XT2–16 [N].
24
XT2
2
1
XT2
2 1
XT2
2 1
XT2 - 15 [L1]
XT2 - 16 [N]
IMPORTANT
Make sure to close the door of the electric box,
firmly at the end of the installation.
NOTE!
For additional information, refer to the wiring
diagram, supplied with the equipment.
E.18 Electrical connections
WARNING
Refer to "Safety Information".
CAUTION
The connection cable must be "H07RN-F"
type, oil proof. Tighten the cables properly
using a maximum torque of 6 Nm.
Make sure the machine power supply voltage specified on the
data plate matches the mains voltage B.3 Machine and
manufacturer's identification data.
Make sure the system power supply is arranged and able to
take the actual current load and that it is executed in a
workmanlike manner according to the regulations in force in
the country of use.
The earth wire from the terminal board side must be longer
(max 20 mm) than the phase wires. Connect the power cable
earth wire to an efficient earth.
The machine must also be included in an equipotential system,
whose connection is made by means of screw EQ (see par.
Installation diagram) indicated by the symbol
equipotential wire must have a section of at least 10 mm
Connect the power cable to the equipment:
• open the door electrical box;
• pass the power cables through hole;
XT2
2 1
XT2
2 1
. The
2
.