PRE-INSTALLATION

Ice Maker
Tubing
20"
83 3/4"
Min. (typ)
*See note below.
to
84 1/2"
78"
approx.
A
24"
Cut-Out Detail for 1 Unit
Cut-Out Width = "A"
Floor under product MUST be at or above the same level as the surrounding FINISHED floor, for ease of installa-
tion and removal.
Electrical: Provide 115 Volt, 60 Cycle, Single Phase, 15 Amp, AC Receptacle. It is recommended that a separate
circuit, serving only this appliance, be provided. *Two (2) units side-by-side require separate circuits, except the
60SS and 72SS (see Instruction Sheet 34361-000). Electrical opening should be placed 78 1/2 inches minimum
from the floor.
Plumbing: Ice maker water supply line (1/4 inch OD copper tubing) to come up the rear of cut-out opening ap-
proximately 78 inches off the floor depending on height adjustment. Tubing should then pass around the right side
of the module and around the front to the solenoid valve (see Installation Instructions provided with the unit).
NOTE: Allow for three (3) inch high removable filler panel for easy removal of power module.
2
Receptacle must be placed in
this location for 18" models.
22"
22"
78 1/2"
Min.
(typ)
83 3/4"
84 1/2"
1/2"
A
A
24"
*Cut-Out Detail for 2 Units
Placed Side by Side
Cut-Out Width = "A" + "A" + 1/2"
Model
18AR
18AF
18TF
18WC
24AR
24AF
to
24TF
24WC
24BC
242Z
30AR
30AF
30TF
36AR
36AF
36TF
36SS
363D
42SS
48SS
54SS
60SS
66SS
72SS
Cut-Out
Width
(inches)
17 1/2
17 1/2
17 1/2
17 1/2
23 1/2
23 1/2
23 1/2
23 1/2
23 1/2
23 1/2
29 1/2
29 1/2
29 1/2
35 1/2
35 1/2
35 1/2
35 1/2
35 1/2
41 1/2
47 1/2
53 1/2
59 1/2
65 1/2
71 1/2