3. TROUBLESHOOTING
Alert no.
Alert name
412431
Serial Buffer Overflow
412432
JB Buffer Overflow
412437
Fatal System Failure
412438
System Information
Error (VDR System In-
formation Error)
412439
Fatal System Error
412451
High CPU Core Tem-
perature
412452
High CPU System
Temperature (CPU
Board System Tem-
perature High)
412453
CPU +3.3V Voltage
Error (CPU Board
+3.3V Voltage Error)
412454
CPU +5V Voltage Er-
ror (CPU Board +5V
Voltage Error)
412455
CPU +12V Voltage Er-
ror (CPU Board +12V
Voltage Error)
412456
CPU VCORE Voltage
Error (CPU Board
VCORE Voltage Er-
ror)
412457
Low CPU Battery Volt-
age (CPU Board Bat-
tery Voltage Lower)
412458
Low CPU FAN Rota-
tion Speed
412459
CPU FAN Not Rotated CPU FAN stopped.
412460
Low External FAN1
Rotation Speed
412461
External FAN1 Not
Rotated
3-10
Description
Serial data from DCU serial
channel (1 - 8 ch) are not re-
corded to Fixed DRU, Float-free
DRU and Long Term Device.
Serial, analog and digital data
from Junction Box (IF-8530) are
not recorded to Fixed DRU,
Float-free DRU and Long Term
Device.
Fatal system error. This indi-
cates that VDR can not be re-
booted automatically.
VDR system information can
not be acquired. Usually, this
error is recovered automatical-
ly.
Temperature of CPU system
high and long term device is
turned off.
Temperature of CPU core is
high.
Temperature of CPU board is
high.
Voltage error on CPU board.
(+3.3 V line)
Voltage error on CPU board.
(+5 V line)
Voltage error on CPU board.
(+12 V line)
Voltage error on CPU board.
(VCORE line)
Voltage of battery on CPU
board is low.
Rotation speed of CPU FAN is
low.
Rotation speed of external
FAN1 is low.
External FAN1 stopped.
Action
Restart VDR. To restart the
VDR, open the DCU door with
its key and turn on the AC and
BATTERY switches on the
power control panel, then turn
the switches on after shut-
down of the DCU. If the error
re-occurs, contact your deal-
er.
If error is not recovered auto-
matically, restart VDR. To re-
start the VDR, open the DCU
door with its key and turn on
the AC and BATTERY switch-
es on the power control panel,
then turn the switches on after
shutdown of the DCU. If it
does not recover, contact your
dealer.
Restart VDR. To restart the
VDR, open the DCU door with
its key and turn on the AC and
BATTERY switches on the
power control panel, then turn
the switches on after shut-
down of the DCU. If the error
re-occurs, contact your deal-
er.