if Sprayer is not properly cleaned immediately after every use.
Clean Sprayer immediately to prevent permanent damage.
3. The smaller the gauge number of the wire, the
greater the capacity of the cord. For example,
a 14 gauge cord can carry a higher current
than a 16 gauge cord. (See Table A.)
4. When using more than one extension cord
to make up the total length, make sure
each cord contains at least the minimum
wire size required. (See Table A.)
5. If you are using one extension cord for more
than one sprayer, add the nameplate amperes
and use the sum to determine the required
minimum cord size. (See Table A.)
6. If you are using an extension cord outdoors, make
sure it is marked with the suffix "W-A" ("W" in
Canada) to indicate it is acceptable for outdoor use.
7. Make sure the extension cord is properly wired
and in good electrical condition. Always replace
a damaged extension cord or have it repaired
by a qualified electrician before using it.
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.

Specifications

Electrical Input
Maximum Working Pressure
Item 62915
RETURNS NOT ACCEPTED & WARRANTY VOID
120  V AC / 60  H z / 7A
3000 PSI
For technical questions, please call 1-888-866-5797.
8. Protect the extension cords from sharp objects,
excessive heat, and damp or wet areas.
RECOMMENDED MINIMUM WIRE GAUGE
FOR EXTENSION CORDS*
NAMEPLATE
AMPERES
25'
(at full load)
0 – 2.0
18
2.1 – 3.4
18
3.5 – 5.0
18
5.1 – 7.0
18
7.1 – 12.0
18
12.1 – 16.0
14
16.1 – 20.0
12
* Based on limiting the line volt-
TABLE A
age drop to five volts at 150% of
V
Volts
~
Alternating Current
A
Amperes
Outlet
Paint Hose
(120/240 VOLT)
EXTENSION CORD
LENGTH
50'
75' 100' 150'
18
18
18
16
18
18
16
14
18
16
14
12
16
14
12
12
14
12
10
12
10
-
10
-
-
the rated amperes.
1/4"–  N PS M
25' Long