Download Print this page

KRAUSE & BECKER 62915 Owner's Manual & Safety Instructions page 13

Airless paint sprayer

Advertisement

if Sprayer is not properly cleaned immediately after every use.
Clean Sprayer immediately to prevent permanent damage.
7. Sprayer will start pumping and water or
flushing solvent as well as air bubbles will
be purged from system. Let fluids discharge
from Priming Tube into waste bucket for 30 to
60 seconds, then switch Power to OFF.
IMPORTANT: If solvent will not flow through
hoses, try pressing the red inlet release button
underneath the pump to loosen the inlet check ball.
8. Remove Suction Tube from water or flushing
solvent and submerge in paint pail.
9. Switch power ON.
Item 62915
RETURNS NOT ACCEPTED & WARRANTY VOID
OFF
ON
For technical questions, please call 1-888-866-5797.
10. Paint should work itself from Suction
Tube to Sprayer to Priming Tube until
paint discharges from Priming Tube.
11. Switch power OFF. Remove the Priming
Tube from the waste bucket and clip to
Suction Tube and submerge in paint pail.
12. Switch power ON. Point gun into
waste bucket and pull trigger.
13. Turn Spray/Prime Switch to Spray mode
and continue to spray into waste bucket.
14. Stop spraying. If the motor stops, the
pump and tubes are primed. If it does
not stop, repeat priming steps.
Page 13

Hide quick links:

Advertisement

loading