1. Fault indicator light
2. Right button—press it to open a menu when a right arrow indicates additional content.
3. Middle button—press it to scroll down the menus or digits for PIN code.
4. Left button (menu access/back button)—press it to access the InfoCenter menus. Also use it to back out of any menu that you
are currently using.
If an electrical fault occurs, the InfoCenter indicator light flashes and a text message appears immediately to
notify you about the fault.
Faults that are currently happening are called active faults. As soon as a fault occurs, information about
that fault is displayed on the InfoCenter. Faults remain active until you clear them or the condition that
created the fault no longer exists.
To see a list of faults that occurred before the most recent starting of the machine, use the InfoCenter
Faults screen. The Faults screen lists all the machine faults that have occurred since the InfoCenter
fault log was last cleared.

Clearing Fault Codes while Using the Machine

If a fault occurs while you are operating the machine, attempt to clear the fault by performing the following steps:
1.
Move the traction lever to the N
2.
Move the key switch to the O
3.
Allow all machine functions to stop.
4.
Start the machine and test it to see if operation has returned to normal.
If a fault repeats each time you start the machine, conduct diagnostic troubleshooting of the affected system
and related components.

Clearing the InfoCenter Fault Log

You can clear the faults from the InfoCenter fault log; however, the fault history will be retained in the TEC-2402
memory.
Note:
Refer to
Figure 7
1.
Press the left button as needed to display the Main Menu.
Note:
If no faults have occurred since the last time the faults were cleared, a No Faults Logged menu
item will be displayed instead of the Faults menu item. Press the left button as needed to exit the Main
Menu.
2.
Press the middle button as needed to highlight Faults, and then press the right button. The Faults
screen appears.