DS-KB8113-IME1(B) Series Vandal-Resistant Door Station User Manual
Press Button to Call
Steps
1. Click Intercom → Press Button to Call to enter the setting page.
2. Check Call Management Centeror Call Specified Indoor Station to set the button.
Note
If you check Call Specified Indoor Station, you should enter the specified indoor station No.
3. ClickBacklight Mode and you can select a backlight mode from the drop-down list.
I/O Settings
Steps
1. Click Intercom → I/O Settings to enter the I/O input and output settings page.
2. Select I/O input No., input mode, output No., and output mode.
3. Click Save to enable the settings.
Note
For door station, there are 4 I/O input terminals. By default, Terminal 1 and 2 correspond to
●
Door Status. Terminal 3 and 4 correspond to interfaces of Door Switch.
For door station, there are 2 I/O Output Terminals. Terminal 1 and 2 correspond to Door
●
interfaces (NO1/COM/NC1; NO2/COM/NC2) of door station. Door 1 is enabled by default. You
can enable/disable IO Out according to needs.
Number Settings
Link the room No. and SIP numbers.
Click Intercom → Number Settings to enter the page.
44