52 Troubleshooting
•
Have any of the fan motors stopped? Use the server management subsystem to check the fan status.
•
Have your fans speeded up in response to an overheating situation?
•
Have your fans speeded up in response to a fan that has failed?
•
Are the fan power connectors properly connected to the front panel board?
•
Is the cable from the front panel board connected to the both the front panel board and to the server board?
•
Are the power supply cables properly connected to the server board?
•
Are there any shorted wires caused by pinched-cables or have power connector plugs been forced into power
connector sockets the wrong way?
Cannot Connect to a Server
•
Make sure the network cables are securely attached to the correct connectors at the system front or back panel.
•
Try different network cables.
•
Make sure you are using the correct and the current drivers. Make sure the driver is loaded and the protocols are
bound.
•
Make sure the hub port is configured for the same duplex mode as the network controller.
•
Make sure the correct networking software is installed.
•
If you are directly connecting two servers (without a hub), you will need a crossover cable.
•
Check the network controller LEDs next to the NIC connectors for activity.
Diagnostics pass but connection(s) fail
•
Make sure the network cables are securely attached.
•
Make sure you specify the correct frame type in your NET.CFG file.The server hangs when the drivers are loaded
NN47250-306 (324121-A Version 01.01)