NOTE ABOUT FUSE SPECIFICATIONS
The air conditioner's circuit board (PCB) may be designed with a fuse to provide overcurrent
protection. This fuse must be replaces with identical component.
The specifications of the fuse, if equipped, are printed on the circuit board, examples of such are
T5A/250VAC and T10A/250VAC.
NOTE ABOUT FLUORINATED GASSES (NOT APPLICABLE TO THE
UNIT USING R290 REFRIGERANT)
This air-conditioning unit contains fluorinated greenhouse gasses. For specific information on the
type of gas and the amount, please refer to the relevant label on the unit itself or the
"Owner's Manual - Product Fiche " in the packaging of the outdoor unit. (European Union
products only).
Installation, service, maintenance and repair of this unit must be performed by a certified
technician.
Product uninstallation and recycling must be performed by a certified technician.
When the unit is checked for leaks, proper record-keeping of all checks is strongly recommended.
The allowed static pressure range of the air conditioner on site is 0-0.80 in-H2O (0-200 Pa).
The data below represents the static pressures at full required air flow used for AHRI testing.
PRESSURE
(Before Jan,1,2023)
PRESSURE
(After Jan,1,2023)
NOTE
The maximum functional total external static pressure can not exceed 0.80 in WC or 200 Pa. The
airflow reduces significantly beyond 0.80 in WC or 200Pa. System design should allow for the
increased resistance of filters as they become dirty.
0.10 in-H2O(25Pa)
0.5 in-H2O(125Pa)
Installation and Operation Manual - VCDxxSA
0.15 in-H2O(37Pa)
0.5 in-H2O(125Pa)
5
0.20 in-H2O(50Pa)
0.5 in-H2O(125Pa)