Installation and Operation Manual - VCDxxSA
Air volume table
External Static
Capacity
Pressure Range
24K(2 Ton )
0 - 0.80 in. w.g.
30K(2.5 Ton )
0 - 0.80 in. w.g.
Fan speed
Electric heater kit
Cooling Turbo
—
Cooling High
—
Cooling Medium
—
Cooling Low
—
Heat Pump Turbo
—
Heat Pump High
—
Heat Pump Medium
—
Heat Pump Low
—
Electric heater kit
15KW
0(Default)
Electric heater kit 1
15KW, 10KW
Electric heater kit 2
10KW, 8KW
5KW
Electric heater kit 3
Cooling Turbo
—
Cooling High
—
Cooling Medium
—
Cooling Low
—
Heat Pump Turbo
—
Heat Pump High
—
Heat Pump Medium
—
Heat Pump Low
—
Electric heater kit
15KW
0(Default)
Electric heater kit 1
15KW, 10KW
Electric heater kit 2
10KW, 8KW
Electric heater kit 3
5KW
24V thermostat
DIP Switch 24V terminal engaged
SW3-4=ON
Y2/Y
SW3-4=OFF
Y2/Y
—
Y1
—
—
—
—
—
B+Y2/Y, W
—
Y1
—
—
SW4-1=OFF
SW4-2=OFF
W1, W2, AUX
SW4-3=OFF
SW4-1=OFF
SW4-2=OFF
W1, W2, AUX
SW4-3=ON
SW4-1=OFF
SW4-2=ON
W1, W2, AUX
SW4-3=OFF
SW4-1=OFF
SW4-2=ON
W1, W2, AUX
SW4-3=ON
SW3-4=ON
Y2/Y
SW3-4=OFF
Y2/Y
—
Y1
—
—
—
—
—
B+Y2/Y, W
—
Y1
—
—
SW4-1=OFF
SW4-2=OFF
W1, W2, AUX
SW4-3=OFF
SW4-1=OFF
SW4-2=OFF
W1, W2, AUX
SW4-3=ON
SW4-1=OFF
SW4-2=ON
W1, W2, AUX
SW4-3=OFF
SW4-1=OFF
SW4-2=ON
W1, W2, AUX
SW4-3=ON
40
Wired controller
Air flow
volume
DIP Switch
Mode
(CFM)
—
Cool
824
—
Cool
759
—
Cool
694
—
Cool
629
—
Heat
788
—
Heat
753
—
Heat
641
—
Heat
524
SW4-1=OFF
SW4-2=OFF
Heat + AUX, AUX
871
SW4-3=OFF
SW4-1=OFF
SW4-2=OFF
Heat + AUX, AUX
841
SW4-3=ON
SW4-1=OFF
SW4-2=ON
Heat + AUX, AUX
818
SW4-3=OFF
SW4-1=OFF
SW4-2=ON
Heat + AUX, AUX
788
SW4-3=ON
—
Cool
988
—
Cool
894
—
Cool
806
—
Cool
712
—
Heat
918
—
Heat
876
—
Heat
665
—
Heat
453
SW4-1=OFF
SW4-2=OFF
Heat + AUX, AUX
1088
SW4-3=OFF
SW4-1=OFF
SW4-2=OFF
Heat + AUX, AUX
1029
SW4-3=ON
SW4-1=OFF
SW4-2=ON
Heat + AUX, AUX
976
SW4-3=OFF
SW4-1=OFF
SW4-2=ON
Heat + AUX, AUX
918
SW4-3=ON