Step 10
The evaporator is assembled in place.
Step 11
Use cable ties to fix the room temperature
sensor as shown in the figure.
Step 12
Reinstall evaporator cover plate.
CAUTION FOR ALL PIPES INSTALLATION
• Insulate all piping to prevent condensation, which could lead to water damage.
• The drainpipe is used to drain water away from the unit. If the drainpipe is bent or installed incorrectly,
water may leak and cause a water-level switch malfunction.
• In HEAT mode, the outdoor unit will discharge water. Ensure that the drain hose is placed in an
appropriate area to avoid water damage and icy conditions on walkways.
• DO NOT pull the drainpipe forcefully. This could disconnect it.
NOTICE
If installed above a finished living space, a secondary drain pan (as required by many building codes),
must be installed under the entire unit and its condensate drain line must be routed to a location such
that the user will see the condensate discharge.
Step 13
Connect the wire according to the wiring diagram.
cable
Step 14
ties
Reassenble the upper cover and Reinstall the filter,
filter cover plate.
Step 15
Connect the pipes and install the drainage pipes.
15
15
Installation and Operation Manual - VCDxxSA