Fault Diagnosis

In the event of a fault, the Charging Indicator on the front of the charger may show the type of
problem.
LED Colour
BLUE
BLUE
GREEN
RED
RED
RED
RED
RED
RED+BLUE
RED+GREEN
CP = Control Pilot cable (provides communication between the charger and vehicle)
PE = Earth cable
PP = Proximity Pilot cable (provides cable type information to prevent cable overloads)
RCMU = Residual Current Monitoring Unit

Disposal

In accordance with European Directive 2002/96/EC on waste electrical and
electronic equipment and its implementation in national law, used electrical
devices must be collected separately and recycled in an environmentally
responsible manner.
Make sure you return your used device to your dealer or obtain information
regarding a local, authorised collection and disposal system. Failure to
comply with this EU Directive may result in a negative impact on the
environment.
QUBEVM-V01-R0 Installation and Operation Manual
February 2023
LED State
1Hz Flashing
Stable
Brightening/Glowing
5Hz Flashing
Stable
1Hz Flashing
5Hz Flashing
2Hz Flashing
2Hz Flashing
1Hz Flashing
Controller
State
Ready
No Fault
Connected
No fault
Charging
No fault
1. Turn power OFF
Fault
2. Turn power back ON
Fault
Ventilation/cooling required
Possible CP- PE short circuit
Fault
Check the CP line
RCMU leakage or
Fault
self-inspection failure
Fault
EV charging socket fault
Possible PP wire disconnection
Fault
Check the PP line
Fault
Circuit overload
Universal Electric Vehicle Chargepoints
Disposal