WARNING: Electrical Power
The setting of the charger output power (Amps) must only be done by a qualified electrical
installer. Incorrect setting may lead to equipment damage and/or personal injury. The current
rating must not exceed the rating of the electrical supply.
By default, the QubEV charger is set to 32 Amps. If a lower
power is required, refer to the steps below:
1. Make sure electrical power to the charger is OFF.
2. Lift the flap on the front of the Charge Control Unit
and locate the Amp Setting Selector.
3. Turn the Amp Setting Selector to the appropriate
position for the required output power rating.
The new setting will take effect when power is
applied to the charger.
4. Close the Charge Control Unit cover.
5. Make a record of the Amps Setting here.
Amps:
Date:
Name:
Signature:

Completion

WARNING: Electrical Power
Testing may require power to be applied while the enclosure is open.
1. Make sure all accessible terminals are secure and have not become loose during
installation.
2. Test in accordance with the current Electrical Wiring Regulations applicable in the region
of installation.
3. Make sure you are satisfied that the installation is complete and is in a safe condition.
4. Make sure the rubber seal is flat and secure within its channel in the front panel.
5. Refit and secure the front panel of the enclosure. Take care not to trap any electrical
cables.