RFID UHF Sensor
9.4 Connections and status indication
The DTE820 is controlled and evaluated via two connections and a status
indication� The following sections describe the connections and the status
indication�
1 GPIO and RS-232 connection, M12 female, 12 poles
2 Status indication, 2-colour LED (red, green)
3 Ethernet and current supply connection, M12 female, 4 poles, D-coded
Load digital inputs and outputs with max� 0�5 A�
Load all digital inputs and outputs used with max� 1�5 A in total�
When using the auxiliary voltage (24 V DC, pin7), load the digital
inputs and outputs with max� 1�1 A�
Load digital inputs and outputs with max� 30 V DC�
Use LPS (Limits Power Source) or NEC class 2 power supplies as external
voltage source�
Observe the additional notes in the data sheet�
12
1
2
3