Torque Chain Attachment; Roller Pump Exploded View/Parts List; Roller Pump General Info - Fimco 3PT-65-6R-BL Owner's Manual

65 gallon 3 point sprayer w/pump, coupler & boomless boom assembly
Table of Contents

Advertisement

A torque chain, 'S' hook, nut and bolt are included in this assembly to secure your pump during operation.
1. Attach one end of the torque chain over the threaded stem of the bolt.
2. Thread the whiz nut onto the bolt. Hand-tighten.
3. Thread the bolt, chain and nut 'pre-assembly' into the threaded hole on the
underside of the pump. Tighten sufficiently.
4. Affix the 'S' Hook to your frame (or hitch). Wrap the chain
around the frame or hitch and 'S-Hook' it in place. Make
sure this connection is very secure! Not having a good,
tight connection may result in the pump spinning on your
PTO shaft and damaging some components of your
sprayer.
*** Insure that this connection point will not allow the roller
pump to spin on the PTO shaft ***
Cast Iron 6-Roller Pump Assembly
#5271706 (Hypro Part #6500C)
* * = Only Available in Repair Parts Kit #7771795 (3430-0380)
Consists of Rollers, O-Ring & Viton Seals
♦♦ = ONLY Available in Complete Assembly
1. Use a pressure relief device on the discharge side
of the pump to prevent damage from pressure
buildup when the pump discharge is blocked or
otherwise closed and the power source is still run-
ning.
2. WARNING: Never pump flammable or explosive
fluids such as gasoline, fuel oil, kerosene, etc. Nev-
er use in explosive atmospheres. The pump should
be used only with liquids compatible with the pump
component materials. Failure to follow this warning
can result in personal injury and/or property dam-
age and will void the product warranty.
3. Never pump acids (i.e. acid fertilizer) with Super
Rollers!
4. Never run the pump faster than maximum recom-
mended speed.
5. Never pump at pressures higher than the maximum
recommended pressure.
6. Never pump liquids at temperatures higher than the
recommended maximum temperatures (140°F/60°
C).
Torque Chain Attachment to a Roller Pump
Roller Pump General Safety Information
7. Make certain that the power source conforms to
the requirements of your equipment.
8. Provide adequate protection in guarding around
the moving parts such as the shaft and pulleys.
9. Disconnect power before servicing.
10. Release all pressure within the system before ser-
vicing any component.
11. Drain all liquids from the system before servicing
any component.
12. Check all hoses for weak or worn condition before
each use. Make certain that all connections are
tight and secure.
13. Periodically inspect the pump and the system com-
ponents. Perform routine maintenance as required.
14. Never operate a gasoline engine in an enclosed
area. Be sure the area is well ventilated.
15. Use only pipe, hose and fittings rated for the maxi-
mum psi rating of the pump.
16. Never use pump for pumping water or other liquids
for human or animal consumption.
Page 11