TESTING THE BEEPER
Test by disconnecting connector and connecting 12V "+" to red wire
and "-" to black ground wire of beeper.
Or put mower in Reverse.
This should cause beeper to activate.
To measure the voltage at the harness:
1. Set DMM to measure voltage.
2. Set mower to REVERSE.
3. Place probes in harness socket.
4. Measurement display should alternate between 0 and 12V.
Confidential & Proprietary – Property of Techtronic Power Equipment – DO NOT COPY or DISCLOSE