TESTING FUEL GAUGE/ HOUR METER

Percent Charge remaining
Approximate charge remaining
1.
Turn Mower switch ON.
2.
Set Volt meter to "DC VOLTS".
3.
Measure battery voltage between
4.
Measure battery voltage between Black and
Confidential & Proprietary – Property of Techtronic Power Equipment – DO NOT COPY or DISCLOSE
Red
and Black wire (below, left)
Blue
wires (below, right) Approximately 51V fully charges, no load
Total hours of use
(mower must be on
Continuously for a minimum
of 6 minutes for time to change)