Attaching A Pc Or Terminal; Leds For Power - IBM 4002-C4A Installation And User Manual

Hide thumbs Also See for 4002-C4A:
Table of Contents

Advertisement

Table 5. LEDs for power and fans (continued)
LED
PS1 (labeled p1) Left side of front
PS2 (labeled p2) Left side of front
The software regularly polls the hardware for power status information. You can
display the status information from any management session. In addition, the
software automatically generates a Syslog message and SNMP trap if a status
change occurs.

Attaching a PC or terminal

To assign an IP address, you must have access to the Command Line Interface
(CLI). The CLI is a text-based interface that can be accessed through a direct serial
connection to the device and through Telnet connections. The CLI is described in
detail in the Brocade Switch and Router Command Line Interface Reference.
You need to assign an IP address using the CLI. You can access the CLI by
attaching a serial cable to the Console port. After you assign an IP address, you
can access the system through Telnet, the Web management interface, or IronView
Network Manager.
To attach a management station using the serial port:
1. Connect a PC or terminal to the serial port of the system using a
2. Open the terminal emulation program and set the session parameters as
Position
panel
panel
straight-through cable. The serial port has a male DB-9 connector.
Note: You need to run a terminal emulation program on the PC.
follows:
v Baud: 9600 bps
v Data bits: 8
v Parity: None
v Stop bits: 1
State
Meaning
Amber
Power supply 1 is installed, but
not connected or a fault is
detected.
Green steady
Power supply 1 is installed and
is functioning normally.
Green blinking
Power supply 1 has input
power, but is not enabled and
has no output power.
Off
Power supply 1 is not installed
or is not providing power.
Amber
Power supply 2 is installed, but
not connected or a fault is
detected.
Green steady
Power supply 2 is installed and
is functioning normally.
Green blinking
Power supply 2 has input
power, but is not enabled and
has no output power.
Off
Power supply 2 is not installed
or is not providing power.
21