Advertisement

Quick Links

PIPE LASER
STONEX SPL1
EN Operating Instruction

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPL1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STONEX SPL1

  • Page 1 PIPE LASER STONEX SPL1 EN Operating Instruction...
  • Page 2 These operating instructions have been drawn up with due care. However, STONEX does not accept any liability for possible errors in these operating instructions and their consequences. Equally, it does not accept any liability for direct losses or consequential losses resulting from improper use of the laser.
  • Page 3: Table Of Contents

    5.4 Buttons of the STONEX SPL1 remote control panel ....15 5.5 Additional displays of the STONEX SPL1 remote control ....15 5.6 Additional button functions of the STONEX SPL1 remote control 16 6 STONEX SPL1 Startup 6.1 Switching on the STONEX SPL1 pipe laser ........16 6.2 Aligning the STONEX SPL1 pipe laser .........16...
  • Page 4: About These Operating Instructions

    STONEX SPL1 pipe laser. Operation, maintenance and care of the laser as well as the warnings and error messages are also described. • Do not use the STONEX SPL1 pipe laser until you have completely read and understood these operating instructions.
  • Page 5: Safety Information

    Therefore, please read carefully through these operating instructions and all notes and follow them while working with the laser. 2.2 Laser radiation The STONEX SPL 1 pipe laser is a Class 3R laser product in accordance with EN 60825-1:2014. LASER RADIATION...
  • Page 6: Power Supply Safety Instructions

    Safety instructions Laser warning Laser exit openings Type label 2.3 Power supply safety instructions WARNING! Destruction! Explosion risk! f Use charger included in the scope of delivery only. f Use the charger in dry rooms only. f Never expose the units to heat or fire. f Check live components regularly and stop using them if they are damaged.
  • Page 7: General Safety Instructions

    Do not use the units as a climbing aid for people or machines. 2.5 Intended use The STONEX SPL1 pipe laser is suitable for measuring tilts and alignments in pipes and sewers. The unit is submersible (IP68). The unit can be operated with a radio remote control or alternatively via infrared.
  • Page 8: Conformity Assessments

    Safety instructions 2.9 Conformity assessments FCC note This unit has been tested and conforms with the limits for a Class A digital device in accordance with Part 15 of the FCC Rules. These limits should provide appropriate protection against harmful interference, if the device is operated in a commercial, industrial or business environment.
  • Page 9: Description Of The Stonex Spl1

    The STONEX SPL1 is a fully automatic laser, which has been developed for use in pipe and sewer constructions. The STONEX SPL1 can be used to sur- vey or measure and lay pipe systems quickly and easily. The innovative shock protection system and the robust, water and dust protected housing protect the laser.
  • Page 10: Structure Of The Unit

    EN Operating Instructions 3.4 Device components STONEX SPL1 pipe laser 1 LED for signalling the laser axis of rotation 2 OLED display 3 Control panel with rubber keypad 4 Handle, rubberised 5 Adjustable feet for pipe (Ø 150mm, 200mm, 250mm, 300mm)
  • Page 11: Technical Data

    EN Operating Instructions 3.5 Technical spezification Pipe laser Pipe laser STONEX SPL1 Ref-No. 472210-318 Self-levelling range: -15% ... +40% Transverse tilt compensation ±5° Vertical adjustment range -15% ... +40% Horizontal adjustment range ±10° Display resolution 0,001% Levelling accuracy ± 5mm over 100m...
  • Page 12: Charging The Battery

    EN Operating Instructions 4 Initial start up STONEX SPL1 4.1 Charging the battery 1 Remove the rubber cover from the charging socket. 2 Connect the adapter cable supplied to connect both units to the charger at the same time. 3 Connect the cable in the charging socket of the unit.
  • Page 13: Stonex Spl1 Controls

    EN Operating Instructions 5 STONEX SPL1 Controls 5.1 Buttons of the STONEX SPL1 control panel BUTTON SELECTION/ VALUE INPUT „upwards“ DISPLAY LED-DISPLAY Tilt adjustment LED-DISPLAY „Rising gradient“ (+) Tilt adjustment „Falling gradient“ (-) LED-DISPLAY Operating state LED- DISPLAY charging BUTTON...
  • Page 14: Stonex Spl1 + Rc Display And Button Functions

    EN Operating Instructions 5.3 Display and button functions STONEX SPL1 and Remote control No. Button/Display Description Up arrow Number selection upwards for tilt input or tilt adjustment upwards in manual mode Tilt indicator Lights up green if a rising gradient (+) is set...
  • Page 15: Buttons Of The Stonex Spl1 Remote Control Panel

    EN Operating Instructions 5.4 Buttons of th STONEX SPL1 remote control panel BUTTON SELECTION / VALUE INPUT „upwards “ BUTTONs Activate settings menu DISPLAY LED-DISPLAY LED-DISPLAY Tilt adjustment Tilt adjustment „Falling gradient“ (-) „Rising gradient“ (+) BUTTON BUTTON Move laser beam...
  • Page 16: Additional Button Functions Of The Stonex Spl1 Remote Control

    EN Operating Instructions 5.6 Additional button functions of the STONEX SPL1 remote control Button Description BUTTON Tilt input / OK The same function as for STONEX SPL1 (for functions, see table on page 15) Manual mode Activate / deactivate manual mode. Laser beam can be set and adjusted using the UP/DOWN/RIGHT/LEFT arrow buttons.
  • Page 17: Adjusting The Tilt

    To confirm the set value, press the TILT/OK button. 7.2 Plumb function The STONEX SPL1 remote control can be used to manually adjust the laser beam vertically. This function can be used to align the laser beam with a target mark above the pipe. After exiting the plumb function the laser beam...
  • Page 18: Measuring And Accepting The Tilt

    EN Operating Instructions 7.3 Measuring and accepting the tilt The STONEX SPL1 remote control can be used to manually align the laser beam vertically with the target plate and the tilt value can be accepted. Button Description To change the tilt manually, press the MANUAL but- ton.
  • Page 19: Unit Settings

    EN Operating Instructions 8 Unit settings The STONEX SPL1 pipe laser provides a unit setting mode with which the laser can be adjusted individually to the needs of the user. The settings can either be selected directly at the laser or using the remote control.
  • Page 20: Unit Menu

    EN Operating Instructions 8.2 Unit menu Symbol Description Vibration sensitivity The threshold of the vibration sensitivity can be switched between OFF, COARSE and FINE. By default, the COARSE threshold is set. The function is active 60 seconds after the laser has levelled itself horizontally.
  • Page 21: Info Displays And Warnings

    Service indicator During start referencing, the laser shows a service symbol at the top left next to the hourglass in the form of a wrench. Remedy: Service is due! Send device for service at STONEX or to an authorized customer service.
  • Page 22: Acoustic Warning Signal

    EN Operating Instructions Displays in the control panel display Symbol Description Sleep-mode display on the remote control: Laser is in standby mode. Remedy: Use the remote control to disable the laser’s standby mode Infrared display on the remote control If the radio connection is disrupted the unit switches to infrared communication automatically.
  • Page 24 Stonex USA 54 Regional Dr. #1 Concord, N.H. 03301 www.stonexamerica.com Art.-Nr. 063338 Subject to technical changes without notice.