9.3. Default Interface ........................... 60 9.4. EDM Settings ............................61 9.5. Date and Time Setting........................63 9.6. Shortcut Keys ............................63 9.7. Other Settings ............................63 9.8. Restore Factory ............................. 64 System Information ........................65 Stonex R20 – User Manual...
Page 4
General warranty for instruments........................ 82 Shipping policy ..............................82 Return policy dead on arrival instruments ....................82 Firmware/Software warranty.......................... 83 Over warranty repair(s) policy........................83 Disclaimer and limitation of remedy......................83 Instrument warranty ............................83 Stonex R20 – User Manual...
Page 5
Environmental recycling ............................84 Stonex R20 – User Manual...
1. Introduction Thank you for purchasing R20 total station from STONEX. This manual includes important safety directions and instructions for setting up and using the product. Please read this manual carefully before using, so that our products can serve you better.
Avoid direct the laser at any highly reflective object that is not a reflector prism or tape, such as windows, • mirrors, traffic signs, etc. Turn off the pointer and plummet laser as much as possible when not working on distance measuring or • centering. Stonex R20 – User Manual...
Prohibit operate near high-voltage power transmission and large power facilities. • Whenever possible, avoid using centering rod near electrified railroads, power lines, etc. • Outdoor work during thunderstorms is prohibited. • Do not operate instruments, batteries, chargers, etc. with wet hands. • Stonex R20 – User Manual...
Do not sit or stand on the transport case, and avoid placing heavy objects on the case. • Do not use a transport case with broken body, damaged hinges, or latches. • Avoid strong vibrations, shocks to the instrument, tripod, transport case, etc. • Stonex R20 – User Manual...
The user of this product should have sufficient measuring skills and use it in accordance with the user • manual. The user should carry out periodic self-check of the instrument's performance. • The manufacturer and its agents cannot be held responsible for the consequences and loss of profit • Stonex R20 – User Manual...
Page 11
The manufacturer and its agents shall not be liable for any direct or indirect consequences and loss of • profit caused by force majeure (such as earthquakes, storms, lightning, floods, fires, collapses, etc.), or by third parties. Stonex R20 – User Manual...
Under ideal instrumentation and set-up conditions, the following properties are desirable: The SA, the laser plummet axis, and the zenith/plumbline are co-linear and pass through the current • station point. The tubular level and the circular level are perpendicular to the SA. • Stonex R20 – User Manual...
Page 15
Function keys. Press to Call up the assigned functions of corresponding softkey. The currently available softkeys are shown in the bottom softkey bar of the workspace on display, up to four of them, can be activated by corresponding function keys. Stonex R20 – User Manual...
Please use the charger and battery from STONEX. Store, use and charge at the specified temperature conditions, taking care to avoid contact with liquids.
] for more than 2 seconds in the power-on state, the instrument will prompt to turn off the power and save the current settings, press [ENT] to confirm and turn off the power. Ensure that the battery is charged and properly installed as required. Stonex R20 – User Manual...
Press [-] in the measurement interface also provides quick access to {Level & Plummet}. The electronic circular level diagram on the left indicates the current leveling state, while the dot at the bullseye indicates leveling. Stonex R20 – User Manual...
The automatic tilt compensation function of the instrument can reduce the influence of SA tilt on the measurement accuracy. When the function of 〈2-Axes〉in {Level & plummet} is switched on, the instrument can automatically correct the error caused by the SA tilt, i.e., it can compensate the VA/HA automatically. Stonex R20 – User Manual...
Page 20
If the instrument is set up on an unstable base (e.g. on a shaking platform, ship, etc.), tilt compensation should be switched off. This avoids unexpected error messages and interrupting the measuring process. Stonex R20 – User Manual...
Generally the interface is divided into three areas from top to bottom, including status bar, workspace and softkey bar. Status bar: Displays the current measurement status information icons under the measurement interface. Other interfaces indicate the name of the current interface or procedure, as well as necessary information icons. Stonex R20 – User Manual...
0% to 100% with a gradient of 10%. 〈2. EDM Set〉 Enter {EDM Setting} for EDM related settings. 〈3. Pointer Laser〉 Switch on/off the red pointer laser to indicate the collimation point at short range. Stonex R20 – User Manual...
The search function requires entering the exact point name. The search can be limited to a specific job or to all records. A fixed point that satisfies the search criteria is always Stonex R20 – User Manual...
The final direction of rotation of the drives are always recommended to be clockwise. Repeat 3 and 4 until the target and reticle image are all clear, and both centers are precisely aligned. Start measuring. Stonex R20 – User Manual...
Indicates that the instrument's bluetooth function is turned on. Telescope Position: Indicates the current status of telescope position/face (I or II). Telescope is on position/face I. Telescope is on position/face II. EDM Type: Indicates the current target type of EDM. Stonex R20 – User Manual...
Page 26
Convert HA incrementation between right and left, i.e., clockwise and 【R/L】 counterclockwise directions. [F3] Vertical angle display format, switch between horizontal zero and zenith 【VA/ZA】 zero. [F4] Turn to the 1 page of softkeys. 【P3/3】 Stonex R20 – User Manual...
[F1] Enter {Offset}. 【Offset】 [F2] Enter {Back Sight}. 【BS】 [F3] Convert distance units between meters and inches. 【m/ft】 [F4] Turn to the 1 page of softkeys. 【P3/3】 5.2. Angle Measurement Measure the HA and VA Stonex R20 – User Manual...
Page 28
When {Unit Setting} 〈AngleUnit〉is set to 〈°′″〉, the integer part of the inputted angle value is degrees, the first two decimal places are minutes, three and four decimal places are seconds, and five decimal places and subsequent numbers will be rounded off. Switch ZA/VA in Percentage Slope Mode Stonex R20 – User Manual...
Page 29
〈ZA〉is the vertical angle that defines the zenith as zero. 〈VA〉is the vertical angle that defines the horizontal as zero. Each time the [F3] key is pressed, the mode switches alternately. This softkey is not available when the vertical angle is switched to slope. Stonex R20 – User Manual...
• to the tape as possible to ensure measurement accuracy. Precise measurement operations must be carried out in the prism mode and the correct prism constant • must be set according to the prism type. Stonex R20 – User Manual...
] in the measurement interface to enter the coordinate measurement mode. Aim at the target, press[F1]【Dist】to trigger the distance measurement and get the coordinates. If no station is set, the default coordinate of current station P is the origin (0,0,0). Stonex R20 – User Manual...
〈User〉(User name can be left out). [F4]【OK】: Set the job as current job. If the application is started without setting a job, the default job will be the previous job. If there is no any job been Stonex R20 – User Manual...
Page 33
): Station coordinates B: Backsight point ): Known coordinates : HA of S-B direction α Angle Orientation: Set orientation by directly inputting an orientation HA of the direction from current station to the backsight point. Stonex R20 – User Manual...
〈dHD〉:The deviation between 〈Calc. HD〉 and 〈HD〉. [F2]【Check】:View the backsight coordinates. [F3]【NO】: Ignore current setting result and back to {BS Coordiantes}. [F3]【YES】: Set the orientation. 6.1. Surveying Application to measure a point and record the data. Stonex R20 – User Manual...
Page 35
1. [F4] 【 All】 : Trigger the distance measurement and record the result. Then automatically adds 1. 〈PointID〉 If not perform distance measurement and directly press[F3]【Rec】, only the angle data would be recorded (no Stonex R20 – User Manual...
Stake out method which is based on a polar coordinate system. The calculated offset is divided into one angle and two distance elements. : Station : Current point : Stakeout point a: dHD (Longitudinal offset) b: dHA (HA offset) c: dh (Height offset) Stonex R20 – User Manual...
Page 37
Record the current point measurement result. [F1]【Rec】: [F2]【HD/Coord】: Switch the method between cartesian and polar. 〈dHD〉: Longitudinal offset. Polar Stake Out: Input the longitudinal offset and HA offset to define the stakeout point. Stonex R20 – User Manual...
Page 38
↑: Move lower. After moving the target according on the guidance, aim at the target again. Then press [F1]【Dist】to trigger the distance measurement again. Repeat the movement and measurement until the offset values meet the requirements Stonex R20 – User Manual...
Distance Offset: Distance offset program requires that the measurement point and the target point are equal in height, and the offset disrtance is known. It is usually used when the target point is not in view. Stonex R20 – User Manual...
Page 40
HA needs to be measured. The application will calculate the coordinates of the target point based on the distance value of the measurement point and the angle value of the target point. This method can Stonex R20 – User Manual...
Page 41
: Length of B-C (known) Hidden Point Offset: Hidden point is a target point that is not directly visible. By using a special hidden-point rod whose length was known, hidden point program can be measured indirectly. Stonex R20 – User Manual...
Page 42
Input the known length between the prism B and the rod tip C. Press [F3] [OK] to display the calculated result of the target point. Convert the display data format between polar and [F3]【Shift】: coordinates. Record the result data of target point. [F4]【Rec】: Stonex R20 – User Manual...
Workspace display the calculated center coordinates and the radius of the cylinder. [F2]【END】: Exit the program Record the center point coordinates. [F3]【Rec】: 7.2. Missing Line Measurement This application is used to measure and calculate the SD/HD/VD of two target points. Stonex R20 – User Manual...
Page 44
[F2]【Move】: Set the second point as new start point. [F3]【SD/Slope】: Switch the display modes between SD and slope. [F4]【MLM】: Re-measure the second point or aim then measure the new second point (remain the same first point). Stonex R20 – User Manual...
Press [3] 〈3.Remote Height〉to enter {Remote Height}. Set up the prism on the measurement point (which is directly below or above the target point). Input the 〈hr〉. Aim at the prism and press [F1]【Dist】to trigger the distance measurement. Stonex R20 – User Manual...
Use the navigation keys to select 〈3.Apps〉and press [ENT], or simply press the numeric key [3] to enter {Applications}. Press [4] 〈4.Area〉to enter {Area Calculate}. Workspace displays the list of target points. [F1]【Dist】: Enter in the point measurement interface to measure a target point. Stonex R20 – User Manual...
[F2]【Cont】: back to the point list and continue to add more points. [F3]【END】: Exit the program 7.5. Resection This application is used to determine the station (instrument) coordinates by measuring and backcalculating some known points. The calculation requires between 2 and 5 known points. Stonex R20 – User Manual...
Page 48
Distance method will measure the distance and the angle of known point. Angle method will measure the angle only. The distance method requires at least two known points to calculate the result. Angle method requires at least three known points for calculation. Stonex R20 – User Manual...
This application can easily stake out or checking of lines for buildings, sections of road, simple excavations, etc. After defining a reference line by two points, the user can use the programs to stake out or measure based on the reference line. Stonex R20 – User Manual...
Page 50
Enter in {Define Ref. (End Pt)} Define the end base point by one of three methods in {Define Record the coordinates. Ref. (End Pt)} . Press [F4]【Rec】to Enter in {Define Refline(1)} to check the base line. Stonex R20 – User Manual...
Page 51
Press [F3]【OK】to calculate and display the coordinates of stakeout point. Press [F1]【StOut】to enter in {Stake Out} program. Following the guide to stake out the target point. Refer to Stake Out. Record the target point coordinates. [F3]【Rec】: Stonex R20 – User Manual...
Page 52
Record the target point coordinates. [F3]【Rec】: Worksapce displays the projection point’s coordinates. Press[F4] 【P1/2】to the 2 interface. Worksapce will display target point’s offset values of the reference line. Press [F1]【StOut】to enter in {Stake Out} program. Following Stonex R20 – User Manual...
Page 53
Refer to Stake Out. Record the projection point coordinates. [F3]【Rec】: Stonex R20 – User Manual...
8.2. Measurement Data The measurement data contains all the recorded data in the instrument internal memory. All the measurement data can be checked, searched or deleted. Stonex R20 – User Manual...
[F2]【New】: Enter {New Point} to create a new fixed point. [F3]【Delete】: Delete the highlighted point record. Press [F4]【P1/2】to 2 page of softkeys, [F1]【First】: Turn to the first page of the list and highlight the first point record. Stonex R20 – User Manual...
The instrument has a USB port, which support USB storge device to perform data transfer. A qualified USB stick is recommended. In {File Manager}press [5]〈5.Data Transfer〉to enter {Data Transfer}. Open the waterproof cover on the instrument's USB port and insert the USB flash drive into it, taking care of the orientation. Stonex R20 – User Manual...
Page 57
[F4]【OK】: Perform the transfer. The data file will create and copy to the default folder named Jobs in the USB stick. The system support four types data file format, TXT, R20, CASS. R20 format is the specialized format for the data conversion software Cube-link or Cube-manager.
〈DataType〉: The datatype to be deleted, can be Job, Measurement or Fixed Point. 〈Job〉: Select Single Job or All Jobs to operate. 〈SelJob〉: If above Single Job was actived, a job name can be selected. [F4]【Delete】: Erase the data selected by above options. Stonex R20 – User Manual...
8.7. Memory Statistic Summary the data by different jobs in the internal memory. In {File Manager} press [7]〈7.Memory Statistic〉to enter {Memory Statistic}. 〈Job〉: Use [ ] [ ] to select the job to be summaried. Stonex R20 – User Manual...
〈Temperature〉:Set the unit of air temperature: ℃/℉. 〈Pressure〉: Set the unit of atmospheric pressure: hPa/mbar/mmHg/inHg 〈DistUnit〉: Set the unit of distance and coordinates: m/US-ft (ft)/INT-ft(fi)/ft-in1/16 〈Decimals〉:Set the number of decimal places of distance and coordinates:3/4 Stonex R20 – User Manual...
Distance measurements are directly influenced by atmospheric conditions on the laser path. Atmospheric corrections are required for precision distance measurements and involved into the VD/HD calculations. Refer to Atmospheric Correction, Refraction and Earth Curvature Correction. Stonex R20 – User Manual...
Page 63
[F2]【Reset】: Reset all input values to 0. [F4]【OK】to confirm the input values. page of softkey [F2]【Times】: Enter {Average Times} to set the number of measuring times of 〈EDM Mode〉Average . The default times is 3. [F4]【OK】to confirm the input value. Stonex R20 – User Manual...
In the measurement interface, press [ ] can directly enter {Area Calculate}. 9.7. Other Settings In {Setting} press [7]〈7.Other〉to enter {Other Setting}. Use [▲] [▼] to highlight a item then use [ ] [ ] to toggle the options available. Press [F3]【OK】to confirm the settings. Stonex R20 – User Manual...
[ ] [ ] to select YES or NO then press [ENT]. If choose YES, all the settings will be reset to default values or options. Restoring the factory settings does not delete any measurement data. To delete the data, refer to Data Delete. Stonex R20 – User Manual...
〈Firmware〉: The current firmware version number of the instrument. 〈EDM-FW〉: The current firmware version number of the EDM. 10.2. System Upgrade The instrument can add applications or enhance performance by updating its firmware. The laterest version of firmware is always recommended. Stonex R20 – User Manual...
Page 67
The instrument automatically updates the firmware. The beep sound continus till the upgrade end. The display will go down for a period of time during this period. After a successful firmware update, the instrument will automatically reboot. Stonex R20 – User Manual...
From version 5.1.xxx of Cube-a it is possible to manage the R20 total station. On cube-a click Device -> Total Station Communication, there will be the page shown in next figure.
Data Transfer). R20 format files exported from the instrument on a USB stick can be converted to other data format by using the Cube-link or Cube-manager software. The Cube-link setup is available on USB stick provided with the instrument. It can be installed on a PC and used directly, whitout need of any license activation.
The HZ-collimation (C) is an error due to the fact that the CA of the instrument is not perpendicular to the TA. In the plane formed by the CA and the TA, the angle between the perpendicular line of the TA through the centre of the instrument and the CA is the HZ-collimation Error (C). Stonex R20 – User Manual...
Calculate the vertical index errore I: − VA − 360°) = If | | > 10", a program calibration is required. Refer to Program Calibration. 12.3. Program Calibration The built-in calibration program can calibrate the following instrument error: Stonex R20 – User Manual...
Page 72
Press [F4]【OK】. Turn to face II, accurately aim at the same target again. Press [F4] 【OK】. Workspace display the new calculated error value and the old value stored. Press [F4]【OK】to confirm the calibration. Stonex R20 – User Manual...
The calculation result is exceeded tolerance due to improper 〈Out of tolerance!Retained〉 operation; the instrument will retain the original set value. 12.4. Mechanical Check and Adjust Check and Adjust the Instrument Plate Level and Tribrach Circular Level Adjusting pin Circular Level Lever Stonex R20 – User Manual...
Page 74
If the displacement is in a clear circular motion and the diameter of the track circle exceeds 3 mm, a calibration is required. The laser plummet calibration needs to be carried out by an authorised service centre. Stonex R20 – User Manual...
Keyboard: Alphanumeric - 24 keys Position: In both faces Trigger key: Available Drives Type: Lock horizontal and vertical drives Internal memory Readings: >80.000 points Max n. of jobs: 30 jobs Export formats: *.r20, *.sdr, *.txt Stonex R20 – User Manual...
Page 77
Standard deviation based on ISO 17123-3 Good condition: cloudy, no haze, visibility about 40km, no heat shimmer, breeze. Under optimal conditions on Kodak Grey Card (90% reflective) Standard deviation based on ISO 17123-4 Time is referring to a single battery Stonex R20 – User Manual...
After long distance transport, the instrument needs to be checked and calibrated according to the operating instructions before the instrument can be used. Battery Transport National and international regulations and guidelines must be followed when transporting batteries. Or contact your local shipping company for related information before shipping. Stonex R20 – User Manual...
Always place the instrument in its case and close the cover when not in use in the field. Cables,Plugs and Charger Keep clean and dry at all times. When not in use, can wipe with a clean, dry cloth. Do not use water or wiping tools with water to clean electrical accessories. Stonex R20 – User Manual...
Atmospheric correction values can be conveniently found on the atmospheric correction chart below. The temperature is read on the horizontal axis of the chart and the pressure on the vertical axis, the value on the diagonal of its intersection is the atmospheric correction value. Stonex R20 – User Manual...
ξ: the ZA (zenith 0) A = (1 – k / 2) / R B = (1 – k / 2) / 2R k: atmospheric refractive index, default 0.13 R: average radius of the earth 6.37 × 10 Stonex R20 – User Manual...
STONEX® sales document or advice that may be provided to Customer by any STONEX® representative in connection with Customer’s purchase of the Product. No change to the conditions of this Limited Warranty is valid unless it is made in written form and signed by an authorized STONEX® supervisor. STONEX ® warrants that: Products are free from defects in materials or workmanship for generally 1/2 year except for accessories or specific parts for which different limited warranty period shall apply.
In no event will STONEX®, its affiliates or suppliers be liable to customer or any third party for any damage in excess of the purchase price of the product.
Page 85
• FOR COUNTRIES OUTSIDE EUROPEAN UNION (EU) • The treatment, recycling, collection and disposal of electric and electronic devices may vary in accordance with the laws in force in the Country in question. Stonex R20 – User Manual...
Need help?
Do you have a question about the R20 and is the answer not in the manual?
Questions and answers
كيف ربط جوالي بالبلوتوث توصل استيشن ستونكس R20