Download Print this page
Hans Grohe Ecostat Square 15714 7 Series Instructions For Use/Assembly Instructions
Hans Grohe Ecostat Square 15714 7 Series Instructions For Use/Assembly Instructions

Hans Grohe Ecostat Square 15714 7 Series Instructions For Use/Assembly Instructions

Advertisement

Quick Links

ZH 用户手册 / 组装说明
EN Instructions for use / assembly instructions
2
4
Ecostat Square
2
Ecostat E
15708007
2
15714XX7
Ecostat S
15758007

Advertisement

loading
Need help?

Need help?

Do you have a question about the Ecostat Square 15714 7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hans Grohe Ecostat Square 15714 7 Series

  • Page 1 ZH 用户手册 / 组装说明 EN Instructions for use / assembly instructions Ecostat E 15708007 Ecostat Square 15714XX7 Ecostat S 15758007...
  • Page 2 中文 备用零件 (参见第页 18) 安全技巧 XX = 颜色代码 装配时为避免挤压和切割受伤, 必须戴上手套. 00 = 镀铬 本产品只允许作为洗浴, 卫生和洁身之用. 14 = Brushed Bronze 不得让儿童和肢体, 精神和/或意识有障碍的成 25 = Brushed Gold-Optic 人在不受监管的情况下使用淋浴系统. 受酒精或 34 = Brushed Black Chrome 毒品影响的人员不得使用淋浴系统. 67 = Matt Black 冷热水管间过大的压力差必须予以平衡. 70 = 镀铬 安装提示 99 = Matt White • 安装前必须检查产品是否受到运输损害. 安装后 选装附件 (参见第页 19) 将不认可运输损害或表面损伤. 不在供货范围内 • 管道和阀门必须根据通用标准进行安装, 冲洗和 • 加长 25 mm #13595000 检查. • 请遵守当地国家现行的安装规定. • 加长件22mm (墙壁不够深时)#13593XX0, #13597000, #15597000 技术参数 工作压强: 最大 1 MPa • 调平装置 1° #95521000 0,1 - 0,5 MPa...
  • Page 3 中文 问题 原因 补救 - 水压不足 - 检查总水压 龙头出水量小 - 调压器过滤网脏污 - 清洁龙头前面和恒温阀芯的过滤 网 - 花洒滤网有垃圾堵塞 - 清洗花洒和软管间的过滤网 - 花洒过滤器元件有垃圾堵塞 - 清洗花洒和软管间的过滤密封件 - 单向阀有垃圾堵塞或漏水 - 清洗单向阀 串水 在龙头关闭的状态下 热水 如有必要则更换新 被强迫流入冷水管路 或者相反 的 - 恒温阀芯未被调节 - 调节恒温器 龙头出水温度和温度设定的不符 - 热水温度过低 - 将热水温度从 升高到 42ºC 60ºC - 恒温阀芯表面结垢 - 更换 水温无法调节 恒温阀芯 - 对于新的安装 - 安装功能块时 基体连接不正确 旋转 180º 可能是...
  • Page 4: Safety Notes

    English Safety Notes Flow diagram (see page 17) free flow Gloves should be worn during installation to prevent  Outlet 1 crushing and cutting injuries.  The product may only be used for bathing, hygienic Outlet 2 and body cleaning purposes. Spare parts (see page 18) Children as well as adults with physical, mental and/ XX = Colors or sensoric impairments must not use this product 00 = Chrome Plated without proper supervision. Persons under the 14 = Brushed Bronze influence of alcohol or drugs are prohibited from 25 = Brushed Gold-Optic using this product. 34 = Brushed Black Chrome The hot and cold supplies must be of equal pressures. 67 = Matt Black Installation Instructions 70 = Chrome Plated 99 = Matt White...
  • Page 5 English Fault Cause Remedy Insufficient water - Supply pressure inadequate - Check water pressure (If a pump has been installed check to see if the pump is working). - Regulator filter dirty - Clean filter in front of the mixer and on the MTC-thermo cartridge - Shower filter seal dirty - Clean filter seal between shower and hose - filter insert shower dirty - Clean filter insert between shower and hose Crossflow, hot water being forced into - Backflow preventers dirty or leaking - Clean backflow preventers, cold water pipe, or vice versa, when exchange if necessary mixer is closed Spout temperature does not - Thermostat has not been adjusted - Adjust thermostat correspond with temperature set - Hot water temperature too low - Increase hot water temperature to 42 ºC to 60 ºC Temperature regulation not possible - thermo cartridge calcified - Exchange thermo cartridge - For new installations: basic body - Install function block turned through incorrectly connected (should be: 180º cold right, hot left) or installed with 180º rotation Safety stop button not operating - Spring defective - Clean spring and/or button,...
  • Page 6 01800187 SW 4 mm (5 Nm) SW 5 mm 1 - 2 m...
  • Page 7 (0,1 Nm) SW 3 mm (1,5 Nm) 15708007 15758007 15714XX7...
  • Page 8 SW 3 mm 例如 42° C for example 42° C...
  • Page 9 SW 3 mm (1 Nm) 15708007 15758007 15714XX7...
  • Page 10 SW 3 mm SW 4 mm...
  • Page 11 SW 27 mm SW 27 mm 红色 / red (8 Nm) (0,1 Nm) SW 4 mm (5 Nm)
  • Page 12 SW 3 mm (1,5 Nm)
  • Page 13 开 / open 关 / close >40° C 热 / hot 冷 / cold...
  • Page 14 • • • • • Hansgrohe , Hansgrohe • • www.hansgrohe-int.com/guarantee. • • QuickClean QuickClean, • •...
  • Page 15: Warranty

    English • After cleaning rinse thoroughly with clean water to Cleaning Recommendation for Hans- remove any cleaner residue. grohe Products • The use of steam cleaners is not permitted. The high Today, modern sanitary and kitchen tapware, showers, temperatures can damage the products. accessories, washstands, tubs and radiators consist of Important very different materials to comply with the needs of the...
  • Page 16 Ecostat E 15708007 55 - 83 15 5 Ecostat Square 15714XX7 Ø 52 - 80 Ø Ecostat S 15758007 Ø 52 - 80 Ø...
  • Page 17 Ecostat E 15708007 Ecostat S 15758007 Ecostat Square 15714XX7 0,60 0,55 0,50 0,45 0,40 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 Q = l/min 9 12 15 18 21 24 27 30 Q = l/sec...
  • Page 18 Ecostat E 15708007 92594000 97350000 96525000 98133000 (M5x20) (16x2) SW 4 mm 98283000 95255000 98793000 (SW 27 mm (Ø 145 mm) 94073000 98156000 (36x2) 98197000 95253000 (20x1,5) 98153000 92279000 98146000 98282007 (30x5) (25x1,5) 92146000 98913000 (25x2,5) (M34x1,5) SW 27 mm 92216000 96454000 95252000 98471000 (44x4) Ecostat S 92280000 15758007 92283000 98153000...
  • Page 19 Ecostat Square Ecostat S Ecostat E 13593XX0 (22 mm) 13597000 (22 mm) 15597000 (22 mm) 98133000 (16x2) 95521000 13595000 (1°) (25 mm)
  • Page 20 Hansgrohe · Auestraße 5 - 9 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440 E-Mail: info@hansgrohe.com · Internet: www.hansgrohe.com...

This manual is also suitable for:

Ecostat s 15758007Ecostat e 15708007