&S Define DSR Option
&V View Active Configuration
&W Store Configuration
&Y Select Power-Up Configuration

+++ Escape

AT Command Set for Nokia 8210
This command defines how the DSR V.24 signal is handled. For some products this
command is a dummy. In these cases, either the DSR is always ON, or the DSR
follows the DTR. (De facto.)
Syntax:
AT&S[0]
AT&S1
This command displays the current values of the S-registers. Values 1 and 2 shall be
present only when stored profiles are supported. Response format is product specific,
but it must fit in a 80x24 character display and all command parameters stored in a
profile must be shown as 'command name'-'values of parameters' pairs (e.g. S7:80).
(V.25ter section 6.1.2.)
Syntax:
AT&V[0]
AT&V1
AT&V2
This command stores the current settings to one of two user profiles. Command
parameters (if implemented) that are stored to a profile are the same as listed under
the command &F (see page 9) except the parameters of the following commands
which are not stored: +CMOD, +CSCA, +CSMP. (De facto.)
Syntax:
AT&W[0]
AT&W1
This command defines from which user profile (0 or 1) parameters are loaded when
the product is activated. This setting is not included in the settings that are stored in a
user profile. The command &F does not affect this setting. (De facto.)
Syntax:
AT&Y[0]
AT&Y1
During on-line data state, the online command state can be entered by giving three
same characters in a sequence. The character is defined by S-register S2. The
default character is '+'. Before and after the sequence there must be a pause of at
least the time defined by S-register S12. By setting S12 to zero, escape sequence
detection can be disabled. (De facto.)
Syntax:
+++
Copyright © 2000. Nokia Mobile Phones. All rights reserved.
Keep DSR always ON.
Enable normal DSR usage. This is the
default option.
View active configuration. (All command
parameter values defined under &F and
&Y settings).
Show settings in stored profile 0. (All
command parameter values defined under
&W).
Show settings in stored profile 1. (All
command parameter values defined under
&W).
Store settings to user profile 0.
Store settings to user profile 1.
Parameters are loaded from user profile 0.
Parameters are loaded from user profile 1.
Enter on-line command state.
'+' is default character.
10