Transport and Unpacking Transport Unpacking Installation of the PC in the control cabinet Earthing measures Power Supply Connection Beckhoff power supply technology Pin assignment of the connector Fitting the cable Material for assembling the connectors Assembling the connectors Connecting Power Supply...
Page 4
Beckhoff branches and partner companies Beckhoff Headquarters Beckhoff Support Beckhoff Service Assembly dimensions Industrial-PC C6930 Industrial-PC C6930 Industrial-PC C6930 with plug-in card slots Industrial-PC C6930 with plug-in card slots Appendix Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference Statement...
Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH. Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH apply.
Hazard to devices and environment If you do not adhere the notice adjoining this symbol, there is obvious Attention hazard to materials and environment. Note or pointer This symbol indicates information that contributes to better understanding. Note C6930...
• if connecting cables internal to the PC are removed or inserted during operation. • if plug-in cards are removed or inserted when the PC is switched C6930...
Read the operating Every user of the Industrial PC must have read these operating instructions instructions. Software knowledge Every user must be familiar with any of the functions of the software installed on the PC that he can reach. C6930...
Product Description Product Description Appropriate Use The C6930 Industrial PC is designed for mounting in control cabinets for machine and plant engineering applications. Front view of Industrial PC C6930 Configuration The C6930 Industrial PC is designed for control cabinet installation. The compact housing is equipped with a 3½-inch motherboard for Intel®...
Replace battery only with the identical type or an alternative type recommended by the WARNING manufacturer. Notice correct polarity! Polarity of the battery: Handling of Lithium Batteries Lithium Batteries should not be recharged, exposed to fire, opened and they should be WARNING protected against sunlight and moisture. C6930...
For optimal cooling the Industrial PC is equipped with a fan cartridge with two fans. The fan cartridge can be exchanged. Replace the fans only with the identical type or an alternative type approved by Beckhoff. View from below Exchanging the fan For exchanging the fan cartridge (1), first solve the knurled screw (2).
Product Description Extension for PCI and PCIe plug-in cards Order option When ordered with the following options the Control Cabinet Industrial PCs C6930-0020 und –0030 can be extended by two additional plug-in card slots: Options C6930-0020 and –0030 C9900-B507 2 PCIe plug-in card slots on the passive backplane integrated inside C6930, to plug-in PCIe x1 cards up to 190 mm (6.3“) length.
The RJ-45 connector (X102) allows the PC to be connected to a 10/100/1000BASE-T Local Area Network (LAN). The Ethernet Port is connected via PCIe, at the C6930-0040/ -0050 the Port is integrated in the chipset. The RJ-45 connector (X103) allows the PC to be connected to a 10/100BASE-T Local Area Network (LAN) (till version –0020) and to a...
4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. C6930...
Installation Instructions Installation of the PC in the control cabinet The C6930 Industrial PC is designed for mounting in control cabinets for machine and plant engineering applications. The ambient conditions specified for operation must be observed (see chapter Technical data).
However, over time this reduces the service life of the battery. The new Beckhoff power supply technology approach addresses this problem and now offers the user the option of switching the PC off without the need for using the battery, thereby reducing the load on the battery.
8-pole plug connector . Pin assignment for Function connecting the switch, the Battery Pack (with UPS only) power supply and the 1 2 3 4 5 6 7 8 battery pack (optional) UPS+ (Output) 24 V DC Power Supply PC_ON Power-Status C6930...
Tighten the lacing cord and pinch off the plastic strap. Fixing the upper part of the strain relief housing Fix the upper part of the strain relief housing by snapping it onto the lower part. C6930...
24 V to 0 V. Via this output a signal lamp can be connected or a contactor for de-energizing the whole system. The maximum load for the Power Status output is 0.5 A and a suitable fuse should be provided. C6930...
Wiring according to the wiring diagram (the circuit of PC_ON and Power- Status is symbolical): Wiring diagram external switch and power supply Connection of the Battery Pack and UPS Output Connection of the Battery Pack and UPS Output only in combination with Note integrated UPS (order option). C6930...
2. Insert the power supply cable that you have assembled into the Industrial PC's power supply socket. Then connect it to your external 24 V power supply. Use same type of rechargeable battery If a 24 V UPS is installed, the same type of rechargeable battery must be used. Attention C6930...
If the PC was ordered without operating system, you have to install the operating system and the driver software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the operating system and the additional devices. C6930...
The device must be fully dismantled in order to dispose of it. The housing can be sent for metal recycling. Observe national Electronic parts such as disk drives and circuit boards must be disposed of electronics scrap in accordance with national electronics scrap regulations. regulations C6930...
The driver software comes with a detailed help function. System The help files can be called up either directly from the configuration register by clicking the Help button, or under via Start > Programs > Beckhoff > UPS software components. C6930...
Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause. Call Beckhoff Service. The Industrial PC does not boot Setup settings are incorrect. Check the setup settings. fully Other cause.
Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com You will also find further documentation for Beckhoff components there.
Assembly dimensions Assembly dimensions Industrial-PC C6930 Assembly orientation The assembly of the unit must take place with the orientation diagrammed here. Attention All dimensions in mm. C6930...
Assembly dimensions Industrial-PC C6930 C9900-M653 Mounting plate at the side wall Assembly orientation The assembly of the unit must take place with the orientation diagrammed here. Attention All dimensions in mm. C6930...
Assembly dimensions Industrial-PC C6930 with plug-in card slots Assembly orientation The assembly of the unit must take place with the orientation diagrammed here. Attention All dimensions in mm. C6930...
Assembly dimensions Industrial-PC C6930 with plug-in card slots C9900-M653 Mounting plate at the side wall Assembly orientation The assembly of the unit must take place with the orientation diagrammed here. Attention All dimensions in mm. C6930...
Appendix Appendix Technical data Industrial-PC C6930 Dimensions: see chapter Assembly dimensions Weight: 2.1 kg (basic configuration) Industrial-PC C6930 Dimensions: see chapter Assembly dimensions with plug-in card slots Weight: 3.6 kg (basic configuration) Do not use the PC in areas The Industrial PC may not be used in areas of explosive hazard.