Advanced Display Settings (P-Settings)

To access P-settings to make various advanced changes, press POWER and
INFO simultaneously. To cycle through the P-settings press the POWER
button. To make changes press the INFO button. To exit P-settings wait for
10 seconds or press POWER and INFO together.
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
P11
P12
P13
P14
P15
P16
P17
P18
P19
P20
P08 – Set to 100% for no speed limit. If top speed is 25mph, a setting of 80%
will set the speed limit at 20mph.
P09 – Important safety feature: Non-zero start on (1) = need to kick the
scooter before accelerator works. Prevents user from accidentally
accelerating while not riding the scooter.
16
Description
Display brightness: 1(low) – 3 (bright)
Display Kilometers (0) or Miles (1)
System Voltage level (do not change)
Sleep timer in minutes
Do Not Change
Wheel diameter (impacts odometer)
Number of magnets on motor
Speed limit 0-100% of top speed
Zero start (0) or Non-zero start (1)
Do Not Change
Electric Braking Strength low (1) to high (24)
Initial Acceleration: soft (1) to strong (5)
Do Not Change
Current amperage limit
Controller cutoff voltage (do not change)
Set odometer to 0
Cruise control on (1) or off (0)
Do Not Change
Do Not Change
Do Not Change
Default
2
1
48
10
0
8
30
100
1
2
1
5
8
12
39
-
0
100
1
4

Advertisement