Accessories; Compliance; Machine Identification; Intended Use - Ferroli RCA 50 Installation, Maintenance And User Manual

Aircooled liquid chillers and heat pumps with axial fans and scroll compressors
Table of Contents

Advertisement

1.3 Accessories

Factory fitted accessories
IM
Automatic circuit breakers
SL
Unit silencement
RFM
Cooling circuit shut-off valve on discharge line
RFL
Cooling circuit shut-off valve on liquid line
CT
Condensing control down to 0 °C
CC
Condensing control down to -20 °C
BT
Low water temperature kit
EC
EC Inverter fans
ECH
EC Inverter fans with high available static pressure
DS
Desuperheater
RT
Total heat recovery
TX
Coil with pre-coated fins
SI
Inertial tank
PS
Single circulating pump
PD
Double circulating pump
FE
Antifreeze heater for evaporator
FA
Antifreeze heater for tank
SS
Soft start
Loose accessories
MN
High and low pressure gauges
CR
Remote control panel
RP
Coils protection metallic guards
AG
Rubber shock absorbers
AM
Spring shock absorbers

1.4 Compliance

The device complies with the following standards:
• Machinery Directive 2006/42/CE
• PED Directive 2014/68/EU
• Electromagnetic Compatibility Directive 2014/30/UE
• LVD Directive: 2014/35/UE

1.5 Machine identification

A Package plate
B Frame feature plate
C Electrical board feature plate
The equipment can be identified from:
• Packaging plate.
- It shows the identification data of the equipment.
• Frame feature plate.
- Affixed on the machine, it shows the technical and performance data of the equipment.
• Electrical board feature plate.
- Affixed on the panel from which the electrical board is accessed, it shows the electrical
data of the equipment.
If it is lost or deteriorated, request a duplicate from Technical Support.
Tampering with, removal and deterioration of the identification plates complicate any
installation, maintenance and spare part request.

1.6 Intended use

This unit is designed to cool water (potentially added with inhibited ethylene glycol) that
circulates in a closed circuit.
The heat pump units can cool or heat the water circuit, depending on the selected operating
cycle.
The heat recovery units can act as a sub-product, heating the water that circulates in a second
closed circuit.
The hot or cold air produced by the machine, may be used for air conditioning systems or
industrial processes.
Any other use of the machine is forbidden.
Do not use flammable products near the machine.
Do not use substances that can form explosive mixtures close to the machine.
Do not use the machine where there are problems of environmental impact.

1.7 General precautions

• These units must be installed by a qualified company that at the end of the work provides the
operator with a declaration of conformity with the regulations in force and the instructions
provided by the manufacturer in this document.
• These units must comply with their intended use in line with their performance
characteristics.
• Wear suitable and accident prevention clothing and equipment during installation and/or
maintenance. The manufacturer declines any liability for non-compliance with safety and
accident prevention regulations in force.
• All unit installation, connection, start-up and shut-down operations must only be
implemented by qualified and authorised personnel.
• Comply with the laws in force in the country where the machine is installed, concerning the
use and disposal of the packaging, the products used for cleaning and maintenance and for
the management when the unit life cycle is complete.
• Any repairs or maintenance must be performed by the technical support of the manufacturer
or by qualified personnel, in accordance with this publication.
• Preferably use original spare parts when replacing components.
• If the refrigerant should leak, ventilate the room. The liquid refrigerant produces toxic gas
when exposed to a flame.
• In the case of a malfunction or spill of liquid or gas refrigerant, set the main switch to "off" and
close the shut-off valves. Promptly call technical support or professional personnel. Do not
intervene personally on the unit.
• If the outside temperature can drop below zero, there is a freezing hazard and the system
must be drained or anti-freeze must be added.
• Based on CE Standard no. 842/2006 on certain fluorinated greenhouse gases, it is mandatory
to indicate the total amount of refrigerant in the installed system. This information is present
in the technical plate found in the outdoor unit.
• This unit contains fluorinated greenhouse gas covered by the Kyoto Protocol. Maintenance
and disposal must be carried out only by qualified personnel.
• This unit contains flammable gas.