Range; Accessories; Compliance; Machine Identification - Ferroli RCA Series Installation, Maintenance And User Manual

Aircooled liquid chillers and heat pumps with axial fans and scroll compressors
Table of Contents

Advertisement

• Inhalation:
- transfer outdoors.
- use oxygen or artificial respiration if needed.
- do not administer adrenaline or similar drugs.
• Contact with eyes:
- rinse thoroughly with plenty of water for at least 15 minutes and consult a doctor.
• Contact with skin:
- wash immediately with plenty of water
- immediately remove all contaminated clothing
Measures in the event of accidental spillage
• Personal precautions:
- Move all personnel to safe areas.
- Provide adequate ventilation.
- Use personal protective equipment.
• Environmental precautions:
- Intercept the emission.
• Cleaning methods:
- Use absorbent products.
Operations with removed panels
Some of the operations and/or tests described below require the removal of the panels to access
inside the unit.
There may be hot surfaces (piping, compressor, etc.) or cold (compressor, intake separator, etc.),
sharp edges (coil fins) or moving parts (fans) even with the machine stationary.
The power supply must be disconnected before removing any panel.
Operations that require the panels to be opened must only be carried out by qualified
personnel wearing personal protective equipment.

1.3 Range

RCA
RCA
RCA
RCA
RCA
RCA
RCA
RCA
1.3.1 Available versions
Cooling only
RCA R AB
Reversible Heat Pump
RCA P AB
Super silenced cooling only
RCA R AX
Super silenced reversible Heat Pump
RCA P AX

1.4 Accessories

Factory fitted accessories
IM
Automatic circuit breakers
SL
Unit silencement
RFM
Cooling circuit shut-off valve on discharge line
RFL
Cooling circuit shut-off valve on liquid line
CT
Condensing control down to 0 °C
CC
Condensing control down to -20 °C
BT
Low water temperature kit
EC
EC Inverter fans
ECH
EC Inverter fans with high available static pressure
DS
RT
TX
EW
PS
PSI
PD
PDI
FE
SS
IS
IST
ISB
ISBT
ISL
ISS
IAV
IAA
IAS
IDL
Loose accessories
MN
CR
RP
AG
AM

1.5 Compliance

The device complies with the following standards:
• Machinery directive 9898/37/EC - 2006/42/EC
• Electromagnetic Compatibility Directive 2004/108/EC
• Low Voltage Directive: 2006/95/EC

1.6 Machine identification

195
220
A
245
270
300
330
360
395
B
B
Desuperheater
Total heat recovery
Coil with pre-coated fins
External water connections
Single circulating pump
Inverter single circulating pump
Double circulating pump
Inverter double circulating pump
Antifreeze heater for evaporator
Soft start
Modbus RTU protocol, RS485 serial interface
Modbus TCP/IP protocol, Ethernet port
BACnet MSTP protocol, RS485 serial interface
BACnet TCP/IP protocol, Ethernet port
LonWorks protocol, FTT-10 serial interface
SNMP protocol, Ethernet port
Remote set-point, 0-10 V signal
Remote set-point, 4-20 mA signal
Remote signal for second set-point activation
Demand limit from digital input
High and low pressure gauges
Remote control panel
Coils protection metallic guards
Rubber shock absorbers
Spring shock absorbers
Packaging plate
Frame feature plate
5

Advertisement

Table of Contents
loading

Table of Contents