For continuous drainage into a floor drain
To operate similar to a stand alone dehumidifier, you may choose to use continuous drain
option.
1.
Turn off the power to the unit and unplug the unit.
2.
Remove the plug of the water outlet opening. (Either middle or bottom)
3.
Attach the drain hose. Ensure that the hose is straight without any knots and clear
of obstruction.
4.
Place the other end of the drainage hose into a floor drain.
5.
Replace the rubber sealing plug after operation to prevent leaks.
CLEANING THE AIR FILTER
The filter should be cleaned about every 2 weeks to maintain proper air flow.
Important :
Do not operate the unit without an air filter, or the evaporator may be
contaminated.
1. Press POWER button to turn OFF the unit. Unplug the unit from the electrical power outlet.
2. Remove the filter from the unit.
3. Use a vacuum cleaner or a wet cloth to clean the air filter. Ensure that the air filter is dry before
placing it back into the unit.
STORAGE
If you will not be using the unit for an extended period of time (more than a few weeks) it
is best to clean the unit and dry it out completely. The unit must be kept in upright position
when in storage.
1.
Unplug the unit and remove exhaust hose and window kit store with the unit.
2.
Drain the remaining water from the unit.
3.
Clean the filter and let the filter dry completely.
4.
Re-install the filter.
5.
Store the unit is a well ventilated, dry area.