Installation Requirements
NOTE:

It is most important that this appliance is installed correctly and that operation is correct before use.
Installation shall comply with local, gas, health and safety requirements.

This appliance shall be installed with sufficient ventilation to prevent the occurrence of unacceptable
concentrations of health harmful substances in the room, the appliance is installed in.
Blue Seal pasta cookers are designed to provide years of satisfactory service and correct installation is essential to achieve the best
performance, efficiency and trouble-free operation.
This appliance must be installed in accordance with National installation codes and in addition, in accordance with relevant National /
Local codes covering gas and fire safety.
AUSTRALIA / NEW ZEALAND:
UNITED KINGDOM:
IRELAND:
Installations must be carried out by qualified service persons only. Failure to install equipment to the relevant codes
and manufacturer's specifications shown in this section will void the warranty.
Components having adjustments protected (e.g. paint sealed) by manufacturer, are only to be adjusted by an
authorised service agent. They are not to be adjusted by the installation person.
Unpacking

Remove all packaging and transit protection from the appliance including all protective plastic coating from the door outer
panel and exterior stainless steel panels.

Check equipment and parts for damage. Report any damage immediately to the carrier and distributor.

Report any deficiencies to the distributor who supplied the appliance.

Check that the available gas supply is correct to that shown on the rating plate located on the inside of the access door.

Check that the following parts have been supplied with the appliance:
G47
Baskets LH 165 x 125mm
Baskets RH 165 x 125mm
Basket Support Frame
Location
1.
This appliance must be installed in a suitably ventilated room to prevent dangerous build up of combustion products.
2.
Installation must allow for a sufficient flow of fresh air for the combustion air supply.
Combustion Air Requirements:
Natural Gas
LPG
Town Gas
3.
Position the appliance in its approximate working position.
4.
All air for burner combustion is supplied from underneath the appliance. The legs must always be fitted and no obstructions
placed on the underside or around the base of the appliance, as obstructions will cause incorrect operation and / or failure of
the appliance.
5.
Components having adjustments protected (e.g. paint sealed) by manufacturer are only to be adjusted by an authorised
service agent. They are not to be adjusted by the installation person.
NOTE:
Do not obstruct or block the appliances flue. Never directly connect a ventilation system to the appliance
flue outlet.
Blue Seal Evolution Series - G47 Gas Pasta Cooker
Amendment 6
- AS/NZS5601
- Gas Installations.
- Gas Safety (Installation & Use) Regulations 1998.
- BS6173
- Installation of Catering Appliances.
- BS5440
- Parts 1 & 2 Installation Flueing & Ventilation.
- IS 820
- Non - Domestic Gas Installations.
3.
3.
1.
3
13m
/hr
3
13m
/hr
3
13m
/hr
5
Installation
© Copyright Moffat Ltd, March 2016