Gas Regulator
- NAT Gas / LPG / Butane Only.
NOTE:
Gas regulator supplied is convertible
between Natural Gas and LP Gas, but
it's outlet pressure is fixed ex-factory
and is NOT to be adjusted.
- Town Gas Only.
1.
Remove slotted cap from regulator.
2.
Turn 'On' gas supply and appliance.
3.
Adjust pressure adjusting screw to achieve correct burner operating
pressure.
NOTE:
Measure operating pressure at manifold test point with two burners
operating at 'High Flame' setting.
4.
Verify operating pressure remains correct (Re-adjust regulator if required).
5.
Screw cap nut back onto regulator.
Gas Type Labels
On completion of gas conversion, replace gas type labels located at:-
- Rear of unit, above gas connection.
- Beside rating plate.
Commissioning
Before leaving installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a 'Commissioning' check of appliance as shown in Installation Section of this manual.
3.
Ensure any adjustments done to components that have adjustments / settings paint sealed are to be re-sealed.
NOTE:
If it is not possible to get appliance to operate correctly, shut 'Off' gas supply and contact supplier of this
appliance.
Blue Seal Evolution Series - G47 Gas Pasta Cooker
Amendment 6
Appendix A: Gas Type Conversion
Warning
D
O NOT USE A NAKED FLAME TO CHECK FOR GAS LEAKAGES
31
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
Cap Nut
Pressure Adjusting
Screw
.
© Copyright Moffat Ltd, March 2016