Download Print this page
Rockwell Automation Allen-Bradley Guardmaster GuardShield450L Quick Start Manual
Rockwell Automation Allen-Bradley Guardmaster GuardShield450L Quick Start Manual

Rockwell Automation Allen-Bradley Guardmaster GuardShield450L Quick Start Manual

Safety light curtain

Advertisement

Quick Links

Quick Start
Original Instructions
450L GuardShield Safety Light Curtain
Catalog Numbers 450L-B4FNxYD, 450L-B4HNxYD, 450L-E4FLxYD, 450L-E4HLxYD
This quick start provides a summary of the basic steps that are required to
configure and run a system using 450L light curtains in minimal time.
IMPORTANT
This guide provides links to resources for more information
and is not a replacement for a complete understanding of
either publication
ATTENTION: See publication
application requirements and functional safety data. You must
read and understand the safety requirements before putting a
system that contains light curtains into use.
LASER LIGHT CLASS 2 HAZARD: Do not stare into the beam.
450L-E light curtains are equipped with an integrated laser
alignment help option.
Product Overview
The 450L GuardShield™ safety light curtain family is designed for use on hazardous
machinery for Point of Operation Control (POC). The product family is certified as
Type 4 electro-sensitive protective equipment (ESPE) (as defined by EN 61496-1
and IEC 61496-2) and can be used in applications that require up to and including
PLe category 4 according to EN ISO 13849-1.
The 450L safety light curtain family consists of two product lines:
450L-B (Basic): Suitable for basic ON/OFF applications.
450L-E (Enhanced): Provides enhanced features for more sophisticated
applications.
Table 1 - Differences Between 450L-B and 450L-E Safety Light Curtain Systems
Description
450L-B
Alignment
Two zone indicator light-emitting
aid
diode (LED)
• Resolution 14 mm (0.56 in.): 0.5...4 m
(1.64...13.12 ft)
• Resolution 30 mm (1.19 in.): 0.9...7.0 m
(2.95...22.97 ft)
Operating
• Reduced operating range (selected with
range
DIP switch):
– Resolution 14 mm (0.56 in.): 0.9...2 m
(2.95...6.56 ft)
– Resolution 30 mm (1.19 in.): 1.2...3.5 m
(3.94...11.48 ft)
• Start modes
• External device monitoring (EDM)
Functionality
• Operating range
• CIP Safety™
Protective
150...1950 mm (5.91...76.77 in.) in 150 mm (5.91 in.) increments
field length
Plug-ins are available to provide for additional functions, like muting. See
publication
450L-UM001
for full specifications, details on both products, and
available accessories.
IMPORTANT
450L-B transceiver stick cannot be operated with a 450L-E
transceiver stick.
450L-IN004
or publication 450L-UM001.
450L-UM001
for safety
450L-E
Integrated laser alignment and two zone
indicator LED
• Resolution 14 mm (0.56 in.): 0.5...9 m
(1.64...29.53 ft)
• Resolution 30 mm (1.19 in.): 0.9...16.2 m
(2.95...53.15 ft)
• Reduced operating range (selected with
DIP switch):
– Resolution 14 mm (0.56 in.): 0.9...4.5 m
(2.95...14.76 ft)
– Resolution 30 mm (1.19 in.): 1.2...8.0 m
(3.94...26.25 ft)
• Start modes
• EDM
• Operating range
• Beam coding
• Blanking
• Muting
• Cascading
• CIP Safety
Requirements
See firmware revision information in publication
the PCDC to download firmware. If you use Connected Components Workbench™
software, version 12 or later is required.
Workflow
1.
Verify that you have all required parts
2.
Configure the light curtain
3.
Assemble, position, and mount the light curtain
4.
Wire, apply power, and align system
5.
Verify correct operation
Step 1:
Verify that you have all required parts
A 450L GuardShield safety light curtain is normally shipped as an individual
component (single transceiver). A functional system includes four individual boxes.
Plug-ins are ordered separately from the transceivers.
Table 2 - Part List for a Complete System
Required
Item
Part
Quantity
450L GuardShield
1
2
transceiver stick
2
1
Transmitter plug-in
3
1
Receiver plug-in
Figure 1 - Contents of the 450L Transceiver Stick Box
Transceiver
Standard
Stick
Mounting Kit
Step 2:
Configure the light curtain
IMPORTANT
Only authorized personnel must perform system
configuration, by any method.
The plug-in that is inserted determines the functionality and operating parameters
of 450L. Configuration can be made either directly at the DIP switches or with
software:
Connected Components Workbench software (450L-E only and requires
450L-AD-OID optical interface device).
Studio 5000 Logix Designer® application if you use the CIP Safety model.
450L-UM001
for information and
Description
Each box contains the following items (shown in
• One stick
• Mounting kit (top and bottom)
• Test rod
• Instruction manual
150 mm (5.9 in.) pigtail with M12 QD connector (male)
Test Rod
Installation
Instructions
Figure
1):

Advertisement

loading

Summary of Contents for Rockwell Automation Allen-Bradley Guardmaster GuardShield450L

  • Page 1 Quick Start Original Instructions 450L GuardShield Safety Light Curtain Catalog Numbers 450L-B4FNxYD, 450L-B4HNxYD, 450L-E4FLxYD, 450L-E4HLxYD This quick start provides a summary of the basic steps that are required to Requirements configure and run a system using 450L light curtains in minimal time. See firmware revision information in publication 450L-UM001 for information and...
  • Page 2 Plug-ins and enclosures are mechanically keyed to help prevent the wrong plug-in from being used. If any resistance is felt when inserting the plug-in, stop and verify that it is assembled at the correct end. Rockwell Automation Publication 450L-QS001A-EN-P - September 2021...
  • Page 3 Do not Start Start connect For cascading plug-in (Cat. No. 450L-APC-IO-8, see publication 450L­UM001). If set with DIP switches. For muting applications, see publication 450L­UM001). Pin 4 connected to pin 8 (short circuited). Rockwell Automation Publication 450L-QS001A-EN-P - September 2021...
  • Page 4 For more information on ILAS system use, see publication 450L-UM001. Verify that the intensity indicator indicates a continuous protective field interruption (minimum one intensity indicator is OFF) while the test rod is within the protective field. Rockwell Automation Publication 450L-QS001A-EN-P - September 2021...
  • Page 5: Approximate Dimensions

    1985.5 (78.17) 2015 (79.33) 2035 (80.12) 450L-E4xL1950YD Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description GuardShield Safety Light Curtain Installation Instructions, publication 450L-IN004 Provides information that is required to install a GuardShield light curtain.
  • Page 6: Rockwell Automation Support

    Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur Allen-Bradley, Connected Components Workbench, expanding human possibility, Guardmaster, GuardShield, Rockwell Automation, and Studio 5000 Logix Designer are trademarks of Rockwell Automation, Inc.

This manual is also suitable for:

Allen-bradley guardmaster 450l-b4fnxyd, allen-bradley guardmaster 450l-b4hnxyd, allen-bradley guardmaster 450l-e4flxyd, allen-br