Nidek Medical OPD-Scan III Operator's Manual

Nidek Medical OPD-Scan III Operator's Manual

Refractive power / corneal analyzer
Hide thumbs Also See for OPD-Scan III:

Advertisement

REFRACTIVE POWER / CORNEAL ANALYZER
REFRACTIVE POWER / CORNEAL ANALYZER
OPD-Scan III
OPD-Scan III
OPERATOR'S MANUAL
OPERATOR'S MANUAL
US Edition

Advertisement

Table of Contents
loading

Summary of Contents for Nidek Medical OPD-Scan III

  • Page 1 REFRACTIVE POWER / CORNEAL ANALYZER REFRACTIVE POWER / CORNEAL ANALYZER OPD-Scan III OPD-Scan III OPERATOR’S MANUAL OPERATOR’S MANUAL US Edition...
  • Page 2 Original instructions : 34-14, Maehama, Hiroishi-cho, Gamagori, Aichi 443-0038, Japan NIDEK CO., LTD. Telephone: +81-533-67-6611 (Manufacturer) Facsimile: +81-533-67-6610 : 3F Sumitomo Fudosan Hongo Bldg., 3-22-5, Hongo, NIDEK CO., LTD. Bunkyo-Ku, Tokyo 113-0033, Japan (Tokyo Office) Telephone: +81-3-5844-2641 Facsimile: +81-3-5844-2642 : 47651 Westinghouse Drive, Fremont, California 94539, U. S. A. NIDEK INCORPORATED Telephone: +1-510-226-5700 (United States Agent)
  • Page 3: Use This Device Properly And Safely

    Use this device properly and safely. BEFORE USE, READ THIS MANUAL. This operator’s manual includes operating procedures, safety precautions, and specifications for the NIDEK REFRACTIVE POWER / CORNEAL ANALYZER, OPD-Scan III. Cautions for safety and operating procedures must be thoroughly understood before using this device.
  • Page 4: Usage Precautions

    Usage precautions Before use • Do not use the device for other than the intended purpose. CAUTION NIDEK will not assume responsibility for accidents or malfunction caused by misuse. • The safety precautions and operating procedures must be thoroughly understood prior to operation of the device.
  • Page 5 • Do not use any power cord other than the one provided. Do not use the provided CAUTION power cord for any other instrument. Malfunction or fire may result. • Install the device in area where the outlet that the mains plug is inserted into is easily accessible during use.
  • Page 6: During Use

    During use • Perform visual and operational checks before using the device. Do not use the CAUTION device if any error is found. Use of a malfunctioning {device} will not produce the expected results and may cause troubles or lead to inappropriate diagnoses that may induce health hazards. •...
  • Page 7 Installing any other Windows application software may lead to abnormal operation of the OPD-Scan III and loss of stored data. In addition, the warranty may not cover the OPD-Scan III if Windows application software other than the OPD-Scan III software is installed.
  • Page 8 CAUTION electrical and electronic equipment that may disturb, or be disturbed by, other equipment. The OPD-Scan III complies with these requirements as shown in the tables in “6.3 EMC (ELECTROMAGNETIC COMPATIBILITY) (page 314)”. Follow the guidance in the tables for use of the device in an electromagnetic environment.
  • Page 9 40 times. Spectrum output of all light source during measurement (maximum light intensity) OPD-Scan III Relative Spectral Distribution Wavelength (nm) * The values in the graph were obtained using separate measurement devices.
  • Page 10 Patient environment The patient environment is the volume of space in which contact can occur between the patient and any part of the device (including connected devices) or between the patient and any other person(s) touching the device (including connected devices). Use devices that comply with IEC60601-1 in the patient environment.
  • Page 11: After Use

    After use • This device uses a heat-sensitive printer paper. To keep the printed data for a long CAUTION period of time, make copies of the printouts. The paper degrades over time and the printed data may become illegible. • When the device is not in use, turn off the power switch and put the dust cover over the device.
  • Page 12: Maintenance And Check

    Maintenance and check • Only service personnel trained by NIDEK are allowed to repair and service the device. CAUTION NIDEK assumes no responsibility for any adverse events resulting from improper ser- vicing. • When performing maintenance work, secure a sufficient maintenance space. Maintenance work in an insufficient space may result in injury.
  • Page 13: Connection To Network

    Connection to Network • To share the database with PCs installed with OPD Software for External PC, do not CAUTION connect them to the network that can connect to the Internet. Configure a local network only with the device, PCs installed with OPD Software for External PC, and other related instruments or software such as Final Fit.
  • Page 15 Table of Contents 1. BEFORE USE ........1 1.1 Device Outline .
  • Page 16 2.5.2 OPD/CT multi measurement (Multi measurement mode) ....72 2.6 OPD Measurement ........... . 77 2.6.1 OPD single measurement .
  • Page 17 3.2 Explanation of Summaries ..........179 3.2.1 Overview.
  • Page 18 Setting barcode reader and magnetic card reader ......263 4.6.3 Copying temporary data (OPD-Scan III)....... . 265 4.6.4 Using on-screen keyboard (OPD-Scan III) .
  • Page 19 6.2 List of Abbreviations ..........313 6.3 EMC (ELECTROMAGNETIC COMPATIBILITY) .

Table of Contents