Summary of Contents for Scaleo medical Shado 200 RGO

  • Page 1 Chart Shado 200 - 240 ® Shower trolley...
  • Page 2: Table Of Contents

    Content Warning and safety instructions Symbols and pictograms ® General information about the Shado Identifying the parts of the Shado ® shower trolleys ..................7 Accessories ............................... 8 Intended use ..............................9 Contraindications .............................. 9 Assembly & commissioning instructions Instructions for assembly ..........................10 Installing the head rail ............................
  • Page 3 EC Declaration of conformity Contact information DOMU097_EN_v3_20221206_Shado® RGO shower trolleys user manual...
  • Page 4: Warning And Safety Instructions

    Warning and safety instructions This user manual contains important safety information concerning the Shado ® shower trolleys. Carefully read this manual before using the equipment. This user manual concerns the shower trolleys Shado® 200 RGO reference S2700121 and the Shado® 240 RGO reference S2700122. For other models of Shado® shower trolleys, please refer to the DOMA019 user manual.
  • Page 5 In the case of a mechanical or electrical problem, please contact SCALEO Medical who will either take care of your problem directly or will refer it to the closest authorized dealer.
  • Page 6: Symbols And Pictograms

    Symbols and pictograms Symbols used in this manual: This symbol is used to point out instructions and information related to safety in the working environment, where injury may occur if the information is disregarded or ignored. Follow these instructions and be careful and attentive at all times.
  • Page 7: General Information About The Shado ® Rgo

    SCALEO Medical offers a complete range of shower trolleys, with six maximum safety loads available: 160 kg, 180 kg, 200 kg, 240 kg, 290 kg and 350 kg. The Shado ®...
  • Page 8: Accessories

    Shado ® 1. One PVC mattress 2. Two high side rails 3. Four side rails unlocking handle 4. One tray tilting control 5. One foot rail 6. Four head rail mount locking nuts (not pictured) 7. Four foot rail mount locking nuts(not pictured) 8.
  • Page 9: Intended Use

    Intended use The Shado ® RGO shower trolleys are conceived to perform cleaning routines and care of dependent or bedridden patients. They combine comfort and safety for both, the patient and the caregiver. The backrest function of the RGO models enable a better comfort for the patient while washing hair.
  • Page 10: Assembly & Commissioning Instructions

    Assembly & commissioning instructions Unpack the parcel with the usual care. Remove the shower trolley from its box after having unlocked the brake pedals. One N°5 Allen wrench and one 13mm flat wrench are necessary (not provided). Instructions for assembly Installing the head rail 1.
  • Page 11: Installing The Foot Rail

    Installing the foot rail The same procedures as for the head rail applies to the left side, but on the right side, the drain hose hook must be installed between the foot rail and the washers and locking nuts. 1. Remove the nuts, 2.
  • Page 12: Attaching The Cushion To The Mattress

    Attaching the cushion to the mattress 1. Slide the strap into the buckle by passing it through the cushion. 2. Pass the strap through the buckle to secure the installation. 3. By adjusting the loop length, the cushion will be fixed to the correct height.
  • Page 13: Instructions For Use Security Devices

    This function requires that the battery has not been removed and that is NOT fully discharged. Contact SCALEO Medical if one of these elements is not working or if some of the parts are damaged. Additional security features of the control box ®...
  • Page 14: Battery Management

    Battery management When the battery discharge threshold is reached, the user is alerted by a beep. If the battery does not recharge quickly, the unit turns off and the raising/lowering functions are not active anymore. A power reserve allows the Shado ®...
  • Page 15: Maintenance Of The Battery

    Always unplug the power cord after each charge, without pulling it to avoid damaging the cord. It is recommended to have 2 batteries to replace the discharged battery with the charged one. Therefore, Shado® will remain functional at all times. Using the external wall charger The external charger allows you to charge one battery while a second battery in being used.
  • Page 16: Brakes And Directional Lock Casters

    • Remove the battery from its compartment, • Store your battery charged in a cool, dry, well ventilated area, • Check periodically (every month) the status of charge of the batteries: even if they are disconnected batteries tend to discharge. Compliance with these precautions will help you keep your batteries longer and use your equipment in the best conditions.
  • Page 17: Raising And Lowering The Stretcher

    Raising and lowering the stretcher The stretcher can be raised by keeping the raising pedal pressed, which is the left one. The actuator will automatically stop when it reaches the highest position. The stretcher can be lowered by keeping the lowering pedal pressed which is the right one.
  • Page 18: Opening And Closing The Rails

    spray water. Raising button Lowering button Head up Head down Opening and closing the rails The complete Shado® range enables the opening and closing of the side rails. Opening the rails Pull at the same time the left and right handles according to the pictures below. During this operation, the side rail must “go down/fall”...
  • Page 19: Sitting Position

    ATTENTION: the rail is not properly locked. The rail is properly locked: the trolley is safe. NEVER move the trolley by the removable rails. The rail attachment could be deteriorated, causing the rail to fail. Sitting position The ergonomic design of the Shado® RGO allows a comfortable sitting or lying down position for the patient.
  • Page 20: Transferring With The Shado Shower Trolley

    Transferring with the Shado ® shower trolley Transfers must be made in the lying down position and on the central section of the trolley in such a way that the weight of the patient is spread according to his weight. It is absolutely forbidden to sit the patient at the extremities of the trolley;...
  • Page 21 10. Release the brake of the wheels and pull the trolley a step further from the bed. 11. Raise and secure the side rail back up. 12. Set the head cushion under the nape of the patient. Transfers using a Trans'Gliss Two caregivers are required, one on each side of the bed.
  • Page 22 2. If you are using a shower trolley with centralized brakes, select the guiding type for the wheels: • Use the free wheels for difficult operations • Use the unidirectional wheels for simple movements. Activating the unidirectional wheels on the opposite side to the user is enough for simple movements.
  • Page 23: Cleaning And Disinfecting

    Cleaning and disinfecting Make sure to unplug the Shado® RGO trolley before going through any kind of maintenance, cleaning, or transport. Daily maintenance Maintenance after each use and between patients The Shado ® must be cleaned and disinfected, like any device having direct contact with the patient skin.
  • Page 24: Periodic Inspection And Preventive Maintenance

    Periodic inspection and preventive maintenance Annual periodical inspection The aim of a periodic control visit is to control the safety and the maintenance issues on the equipment. This control, as well as the preventive maintenance must be performed regularly every year–...
  • Page 25 The equipment should not be used until the problem is corrected. One copy of this form should be handed to the customer, one copy held by SCALEO Medical and one copy by the authorized distributor.
  • Page 26: Technical Specifications

    They may be required to be replaced during the lifetime of the equipment. SCALEO Medical engages to have on stock all spare parts for a period of 10 years. Maximum tilts...
  • Page 27 Dimensions with the tray on the lower position, horizontal Maximum tilt Trendelenburg angles Shado ® 200 RGO Shado ® 240 RGO Maximum load capacity 200 kg 240 kg Tilting degree of the stretcher +7,5° / - 2°, ± 1° Ground clearance 55 mm Wheels/casters Four 3 positions casters, operated by pairs...
  • Page 28 ® ® Shado 200 RGO Shado 240 RGO Voltage 240V 50/60 Hz (1) Standard charger Charging voltage 27,6 VDC ± 2% Charging current Max. 400mA Charging time 8 hours max. Number of cycles; Up and down » 40 cycles with full battery IP protection IP65 (protected against splashing water) Fire resistance...
  • Page 29: Technical Specifications Of The Accessories

    The dimensions of the models manufactured in series can slightly vary due to variations on the assembly process. Other specifications Environmental tolerance for use Input AC voltage range From 100 to 240 V AC ± 10% Humidity limitation 30 to 90% humidity Temperature limits From + 5 °...
  • Page 30 Technical specification of the wall charger: Input AC voltage range 100~240V AC Input AC frequency range 50/60Hz, Maximum charging current 650 mA Compliance to standards EN 60601-1 :2005 +C1:2006 +C2:2007 , RoHS Charging time 4h 30 Conditions of use Indoor use only DOMU097_EN_v3_20221206_Shado®...
  • Page 31: Electromagnetic Compatibility (E.m.c)

    Electromagnetic compatibility (E.M.C) • The Shado ® shower trolleys require special care regarding the E.M.C. They must be installed and commissioned considering the EMC information provided in this user manual. • ® The RF communication devices and portable phones may affect the Shado shower trolleys.
  • Page 32 Non applicable 0,35 Non applicable Non applicable Directives and manufacturer's declaration - electromagnetic immunity The Shado® is designed to be used in the electromagnetic environment specified below. The user should ensure it is used in such an environment. INMMUNITY Test level - IEC Level of Electromagnetic environment guidelines test...
  • Page 33 Portable and mobile RF communications should not be used closer to any part of the Shado®, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of transmitter. Recommended separation distance Conducted 3 Vrmsf 150 kHz to applicable Non applicable disturbances...
  • Page 34: Warranty

    Warranty The Shado ® shower trolleys have a two (2) years warranty, except for the battery and the accessories that are guaranteed one (1) year. • Any intervention on the device contrary to this manual will entirely void the warranty. •...
  • Page 35: Liability

    Liability SCALEO Medical assumes no liability for any injury or harm and consequences thereof directly or indirectly caused to operators, patients, or any third party in the following cases: • Non-compliance with the instructions or recommendations supplied within this User Manual.
  • Page 36: End Of Life, Recycling

    End of life, recycling The Shado ® shower trolleys and accessories are at least 90 % recyclable. The end of life disposal of the device must be done respecting the recycling circuit and local relevant regulation. This particularly concerns the electrical and electronic equipment (WEEE) and the lead battery (B/A).
  • Page 37 EC Declaration of conformity DOMU097_EN_v3_20221206_Shado® RGO shower trolleys user manual...
  • Page 38 DOMU097_EN_v3_20221206_Shado® RGO shower trolleys user manual...
  • Page 39 DOMU097_EN_v3_20221206_Shado® RGO shower trolleys user manual...
  • Page 40 Contact information The information and advice provided in this user manual are also intended to inform you of the importance of paying attention to safety measures and the necessity of regular maintenance. This is a matter of responsibility for your establishment, and a question of safety for your patients and staff.

This manual is also suitable for:

Shado 240 rgo

Table of Contents