PROGRAMING INSTRUCTIONS
Depress and hold Cancel button until display lights up (Approx. 10 seconds).
You are now in the Program Mode. Functions to be programmed appear in the order in which they are
shown in the following table.
Use the Cancel button to cycle through the functions to find the one you wish to change.
Use the BREW 1 button to lower the displayed value and the BREW 2 button to raise the value. Press
Cancel to store the changed value and advance to next function.
If the Brewer detects no activity for approx. 60 seconds it will exit the Program Mode, except as noted
below.
CODE
FUNCTION TO SET
1A
Brew 1 time
1b
Brew 2 time
2
Visa-brew time
3
Water Temperature 1
4
Auto Arm
5A
Pre-infusion 1 mode
5b
Pre-infusion 2 mode
6
Pulse brew mode
Pulse brew 1 time
6A
6b
Pulse brew 2 time
7A
Audible alert mode
7b
Audible alert no. of beeps
Coffee freshness monitor
8
(Not all models)
9A
Filtering flow rate
9b
Filter capacity
10
Number of Brews
12A
Power mode
12b
Power shutdown time 5
End
None 6
1.
Brewer will remain in this sequence indefinitely until CANCEL button is pressed. Heating icon will
track heater operation.
2.
Hidden if pulse brew mode is OFF or brew 1 time is OFF.
3.
Hidden if pulse brew mode is OFF or brew 2 time is OFF.
4.
Hidden if filter flow rate is OFF.
5.
Hidden when power save mode is normal.
6.
Program mode will time out in 15 seconds at end of programming sequence.
ERROR MESSAGES
The following table explains the error messages which may be encountered on the brewer. The error
messages may be cleared by going into the program mode, using the brew buttons to display "Clr" and
then pressing the cancel button.

ERROR MESSAGE

Er1
Er2
Er3
Er4
Ful
SET VALUES AVAILABLE
OFF, 30 seconds – 6 minutes
OFF, 30 seconds – 6 minutes
OFF, 30 seconds – 2 ½ minutes
170 °F – 205 °F
ON or OFF
ON or OFF
ON or OFF
ON or OFF
2
0 seconds – 60 seconds
3
0 seconds – 60 seconds
ON or OFF
OFF, 1 - 9
10 minutes – 2 hours
OFF, 0.25 – 1.00 gal. / min
4
OFF, 0.50 – 2.50 gal. X 100
ON or OFF, Clr
Normal, Power Save, Power Down
30 minutes – 4 hours
N/A
DESCRIPTION
The fill solenoid has either run for more than six minutes on the initial
Fill run error
tank fill or 3 minutes in normal operation.
Heater run error
The tank heater has run for more than 30 consecutive minutes.
Shorted probe
Short in the thermistor circuit.
Open probe
Break in the thermistor circuit.
Filter limit reached
The selected filtering capacity of the filter has been reached
LIGHTS ICON ADJACENT TO
BREW 1
BREW 2
BREW 1 and BREW 2 (both flashing)
SERVICE
HEATING, (flashing)
BREW 1, (pulsing), COFFEE MONITOR
BREW 2, (pulsing), COFFEE MONITOR
BREW 1 and BREW 2 (pulsing)
BREW 1 (pulsing)
BREW 2 (pulsing)
None
None
COFFEE MONITOR
WATER FILTERING
WATER FILTERING, (flashing)
BREW 1 and BREW 2
None (Displayed P: n, P: s and P: d respectively)
None
"END"
CAUSE
Man PN 151680 Iss 0503