(3) Combined operation mode 1 (Pr. 79 "operation mode selection" = 3)
The start signal is an external signal.
The frequency setting signal is made setting using the optional
control panel or parameter unit.
Preparation
Start signal ............. Switch, relay, etc.
Operation unit......... Control panel (FR-PA02-
Connection cable ... Refer to (1) PU operation mode.
FR-E5P (option) ..... Refer to (1) PU operation mode.
(4) Combined operation mode 2 (Pr. 79 "operation mode selection" = 4)
The start signal is entered from the operation command key
of the optional control panel.
The frequency setting signal is set using the external
frequency setting signal.
Preparation
Frequency ................ 0 to 5V, 0 to 10V or 4 to 20mA DC
setting signal
Operation unit........... Control panel (FR-PA02-
Connection cable ..... Refer to (1) PU operation mode.
FR-E5P (option) ....... Refer to (1) PU operation mode.
parameter unit (FR-PU04)
signals from an external
potentiometer or from outside the
inverter
parameter unit (FR-PU04)
47
OPERATION