FEM4X, FEM4P, REM4X, REM4P: Installation Instructions
THERMOSTAT
R
G
C
W
2
WHT
E
L
O
Y
FAN HUMIDIFIER
115V
M
Fig. 19 – Wiring Layout of Humidifier to Heat Pump
Start-up procedure
Refer to outdoor unit Installation Instructions for system start-up
instructions and refrigerant charging method details.
CARE AND MAINTENANCE
The system should be regularly inspected by a qualified service
technician. Consult the servicing dealer for recommended frequency.
Between visits, the only consumer service recommended or required is
air filter maintenance and condensate drain operation.
AIR FILTER
Inspect air filters at least monthly and replace or clean as required.
Disposable type filters should be replaced. Reusable type filters may be
cleaned by soaking in mild detergent and rinsing with cold water. Install
filters with the arrows on the side pointing in the direction of air flow.
Table 4 – Air Delivery Performance Correction Component Pressure Drop (in. w.c.)
UNIT SIZE
18
FEM4P24
FEM4X24 & REM4X24
FXM4X24
30
36
FXM4X36
42
48
FXM4X48
60
FXM4X60
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
FAN COIL
HEAT PUMP
(CONTROL)
(CONTROL)
RED
R
R
GRY
G
BRN
C
C
WHT
W
2
BLU
W
3
VIO
E
W
2
O
Y
RELAY
HUMIDISTAT
at Indicated Airflow (Dry to Wet Coil)
500
600
700
800
900
0.034 0.049 0.063
0.049 0.063 0.076 0.089
0.026 0.038 0.049 0.059
0.016 0.027 0.038 0.049 0.059
0.049 0.059 0.070 0.080
THERMOSTAT
R
G
W
Y
FAN HUMIDIFIER
115V
M
A95294
Fig. 20 – Wiring Layout of Humidifier to Fan Coil
CONDENSATE DRAIN
During the cooling season check at least monthly for free flow of
drainage and clean if necessary.
PRODUCT DAMAGE HAZARD
Failure to follow this caution may result in poor unit performance
and/or product damage.
Never operate unit without a filter. Factory authorized filter kits may be
used when locating the filter inside the unit. For those applications
where access to an internal filter is impractical, a field-supplied filter
must be installed in the return air duct system.
CFM
1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000
0.070 0.080 0.090 0.099
0.055 0.064 0.073 0.081
0.049 0.056 0.063 0.070
10
FAN COIL
(CONTROL)
RED
R
GRY
G
WHT
W
2
WHT
BLU
W
3
VIO
E
BRN
C
HUMIDISTAT
with Electric Heat
CAUTION
!
0.063 0.070 0.076 0.083 0.090
0.038 0.043 0.049 0.054 0.059
0.049 0.054 0.059 0.065 0.070
0.027 0.031 0.035 0.039 0.043
AIR COND.
C
Y
A95295

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fem4pRem4xRem4p

Table of Contents