  • Page 1 INSTRUCTIONS FOR INSTALLATION AND USE GGS8P - GGS12P - GGPS8P - GGPS12P GES8P - GES12P - GEPS8P - GEPS12P RANGE WITH OVEN FOR RESIDENTIAL AND PROFESSIONAL USE...
  • Page 3: Table Of Contents

    WHAT TO DO IN THE EVENT OF A BREAKDOWN ..............28 PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME ..28 MAINTENANCE (only for qualified personnel) ................28 INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS ............28 Officine Gullo...
  • Page 4: Installation Manual

    INSTALLATION MANUAL Fig. A/1 GES8P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 5 Fig. A/2 GES12P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 6 Fig. A/3 GEPS8P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 7 Fig. A/4 GEPS12P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 8 Fig. A/5 GGS8P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 9 Fig. A/6 GGS12P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 10 Fig. A/7 GGPS8P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 11 Fig. A/8 GGPS12P E.Electrical Connection G. Gas Connection Officine Gullo...
  • Page 12 Einspritzventil flamme Injecteur feux Injector cooking rings Inyector fuegos Regolazione aria Luftregelung Réglage d'air Air regulation Regulación aire 2. Air regulation 4. Thermocouple Candela accensione Zündkerze Bougie d'allumage Lighting spark plug Candela encendido Termocoppia Thermoelement Thermocouple Thermocouple Termopar Officine Gullo...
  • Page 13 4. Pilot bracket Candela accensione Zündkerze Bougie d'allumage Lighting spark plug Candela encendido Termocoppia Thermoelement Thermocouple Thermocouple Termopar Staffa pilota Bügel Leitflamme Bride veilleuse Pilot bracket Brida del piloto Fig. F (oven) FIG. J (FORNO, FOUR, BACKOFEN, OVEN, HORNO) Officine Gullo...
  • Page 14 Fig. G Coup de feu Injector Pilot Officine Gullo...
  • Page 15 Fig. H ELECTRICAL SCHEME TOP   Electrical connection Push-button starting burner 3/4. Power-station starting burner Officine Gullo...
  • Page 16 Fig. I WIRING DIAGRAM STATIC OVEN GN2/1 Commutator Junction-box Element White light Green light Thermostat Safety thermostat Officine Gullo...
  • Page 17: Declaration Of Compliance

    DECLARATION OF COMPLIANCE This appliance is manufactured by OFFICINE GULLO S.r.l Headquarters and factory Via Della Torricella 29, Antella, Bagno a Ripoli 50012 Florence - Italy Tel. +39 055 65 60 3324 +39 055 62 18 07 officinegullo.com | info@officinegullo.com The manufacturer declares that the appliances are compliant with the prescriptions of the EEC norm 2009/142 for the gas part and with norm 2006/95/CE, 2004/108/CE for the electric part.
  • Page 18: Electric Technical Data Table

    ELECTRIC TECHNICAL DATA TABLE Tot. Max. Power Dimensions MODEL Power Supply power absorb supply (KW) cable mm² GGS8P 80x70x90h 230V~ 50/60 Hz 0,01 0,04 GES8P 80x70x90h 400V~3N 50/60 Hz 10,4 5x1,5 GGS12P 120x70x90h 230V~ 50/60 Hz 0,01 0,04 GES12P 120x70x90h...
  • Page 19: Checking For Adequate Ventilation

    All our appliances undergo careful testing: the type of gas, the operating pressure and the category are indicated on the data plate. NB: The year of the appliance manufacture is shown in item “N” on the data plate. The first two numbers (e.g. 08..) represent the year of manufacture. Officine Gullo...
  • Page 20: Electric Connection

    Connection with natural gas H G20 The connection pressure for natural gas is 20 mbar. Check the plate, read the pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer. Officine Gullo...
  • Page 21: Checking Primary Air To The Main Burners And Pilot Nozzles

    Consumption Primary air h=mm Oven Burner max 11 kW- min. 3,5 kW Burner injector 1/100 mm Min. output adjustment 1/100 mm adjustable Pilot Injector 1x19 1x19 1x27 0.859 kg/h 0.859 kg/h 1.164 m3 st./h Consumption Primary air h=mm Officine Gullo...
  • Page 22 Air adjustment (mm) 10,0 10,0 10,0 Oven Burner max 6,5 kW- min. 2,2 kW Injector (marking) By-pass (screw asjustment (number of turns anti- clockwise from fully closed position) Air adjustment (mm) 14,0 14,0 14,0 Pilot injector Officine Gullo...
  • Page 23: Rules For Converting And Installing Other Types Of Gas

    Adjust the minimum flame by turning the by-pass screw either to the right or to the left until heat output reaches 4 kW. The primary air of the all plate burner does not need adjusting. Attention: If liquid gas is used, the minimum flame adjustment screw must be screwed right down. Officine Gullo...
  • Page 24: Checking Functioning

    The cocks can be changed by removing the front panel; to change the thermocouples and burners you have to remove the rungs and trays. Gas oven: the gas-cock, timer, thermocouples, burners and ignition plugs can be changed by accessing them inside the oven and/or by removing the bottom oven panel or control panel. Officine Gullo...
  • Page 25: User Manual

    If the flame goes out you have to repeat the procedure. By turning the knob round to the position the burner is at maximum. By turning the knob round to the position the burner is at minimum. To switch off, move the knob back into position " 0". Officine Gullo...
  • Page 26: Lighting And Regulating Gas Oven Burner

    30 minutes. All cooking times are based on a preheated oven unless otherwise stated in the recipe. Caution: when the oven is on the door must be kept shut otherwise the knobs and protection sheet could get hot and be damaged. Officine Gullo...
  • Page 27: Cleaning And Maintenance

    Do not use abrasive pads or any other chemical products. Cleaning brushed steel surfaces All the brushed steel surfaces should be cleaned using degreasing products or products specifically designed to be used on steel and, where necessary, extra-fine steel wool or extra-thin sandpaper. Officine Gullo...
  • Page 28: What To Do In The Event Of A Breakdown

    Supplying the appliance with gas again must only be possible manually. NATURAL DISCHARGE NATURAL DISCHARGE FORCED DISCHARGE FORCED DISCHARGE Fig.1 Fig.1 Fig.2 Fig.2 1. Extractor hood 1. Extractor hood 1. Extractor hood 1. Extractor hood 2. Interlocking 2. Interlocking Officine Gullo...
  • Page 29 FORCED DISCHARGE Fig. 3 Fig. 4 1) Anti-wind (blow back) chimney 1. Extractor hood 2. Interlocking Type “B11” appliances are supplied upon request with chimney or chimney and anti-wind (blow back) device to be assembled and delivered separately. Officine Gullo...
  • Page 30 Officine Gullo...