Section 9 - Troubleshooting

Machine functions will not operate
Adequate fuel supply?
Proper fuel blend (i.e. winter blend in cold weather)?
Battery properly connected?
Battery fully charged?
Circuit Breaker tripped?
Function toggle switch or the Enable Switch not activated?
Selector Key Switch in proper position?
Both Emergency Stop Switches reset?
Hydraulic fluid level low?
Obvious fluid leak or damaged component?
Wires disconnected, broken, or loose?
GP400 Diagnostic LED OFF?
LED should be ON. If not ON or FLASHING, refer to Service & Parts Manual or contact MEC
Technical Support
Error code at Onboard Diagnostic Center?
See Troubleshooting section in the Service & Parts Manual or contact MEC Customer
Service.
Page 43
Troubleshooting
Troubleshooting
Should you experience erratic operation or notice any malfunction while
operating this machine, discontinue use immediately.
Call for assistance and report the incident to your supervisor, and do
not use the machine until it has been checked by a trained, qualified
mechanic.
Lower Controls
Onboard Daignostic
Center
ART_4737
65-J Diesel - Operator's Manual
GP400 Module
Diagnostic LED
Terminal Block
Module
September 2022