25
5"
Make
sllre the slip
rings are
free
of dirt
and
damage"
If
neces$ary,
clean
ttrrem
with
a
clean
lint-free cloth.
If
they
are rusted
or
damaged,
remove
the stator and
dress
them
with fine
emery
cloth
(No.
500-600)"
9-10
TNSPECTION
OF FIELD WINDING
(FC)
1.
Rernove
the
two 5 mm
screws
and
take
off
the
end
cover"
2. Disconnect each
wire lead
and remove
the two
5
rnrn
screws.
Remove
the
brush holder.
3.
Using
an
ohmmeter,
measure
the
resistance
between
the
slip
rings.
Specifred resistance:
60
70n (20'C or
68oF,
cold)
Replace
the rotor
if
the
resistance
is
zera
(0) or
if
there
is no continuity.
4. Install the
brush
holder and connect the wire
leads.
With
the
generator
running
at
rated
speed, measure
the
voltage
across
the
brush
holder
terminals.
Specified
voltage:
D-C
25.5
39V
(50H2)
D-C
t7
24Y
(60H2)
NOTE: Take note
of
the polarity
of
the
tester
probes
and
wire
leads. Connect
the positive
(+)
wire
lead
flrght
greenfwhite
lead)
to
the
positive
(+)
side
terrnfual
of
the
brush holder.
9.11
INSPECTTON
OF
STATOR AUXILTARY
IryINDTNG
(EC]
1-
Disconnect
the
8-P coupler and check
for
continuity
between
the light
greenlied
lead and green
lead
of
the
coupler.
Resistance: 2.tr50
approx.
(20oC
or 68"F)
(50H2)
l.v fi
approx"
(20"C
or 68"F)
(60H2)
Replace
the stator
if
there is
no
continuity.
Date
of
lssue:
Dec","1977
o
l-loNDA
MOTOR
CO", LTD.
Fig"
9-16
(1)
Slip
ring
Fig"
9-17
(1)
Slip
iing
Fig"
9-18
(L)
Brush holder
(t)
8-P
coupler
(2) Lisht
gieen/red
(3)
Green
lead
(2)
Tester
C
(2)
(3)
(4)
Tester
Positive
(+)
side
terrninal
Negative
side
terrninal
,p
Fig.
9*
19
lead
(4)
Tester
h'