5-8. TIG Lift-Arct Connections

NOTICE − HF Arc Starters will damage this unit.
Do not use high frequency devices with this unit.
7
OM-282217 Page 22
5
6
3
2
1
NOTICE − HF Arc Starters will
damage this unit. Do not use high
frequency devices with this unit.
1
Work Output Terminal
Connect work lead to work output
terminal.
2
Electrode Output Terminal
Connect TIG torch with gas valve to
electrode output terminal.
3
Gas Cylinder
4
Cylinder Valve
Open valve slightly so gas flow
blows dirt from valve. Close valve.
5
Regulator/Flowmeter
6
Flow Adjust
Typical flow rate is 15 cubic feet per
hour (7.1 liters per minute).
Connect
torch
gas
4
regulator/flowmeter.
7
Gas Valve
Valve controls gas preflow and
postflow. Open valve on torch just
before welding.
Tools Needed:
11/16 in., 1-1/8 in., (21 mm)
hose
to
279988-B