EMF DATA SHEET FOR ARC WELDING POWER SOURCE
Product/Apparatus Identification
XMT 350 MPA 230-460 AUTO-LINE W/AUX PWR, (CE)
XMT 350 MPA 230-460 AUTO-LINE W/AUX PWR, TWECO, (CE)
XMT 350 CC/CV 230-460 AUTO-LINE W/AUX PWR, & (CE)
INVISION 352 MPA 230-460 AUTO-LINE W/AUX PWR, & (CE)
ALUMAPOWER 350 MPA 230-460 AUTO-LINE W/AUX PWR, (CE)
XMT 350 FIELDPRO 230-460V, (CE), DINSE
XMT 350 FIELDPRO 230-460V, POLARITY REVERSING, CE,
DINSE
Compliance Information Summary
Applicable regulation
Reference limits
Applicable standards
Intended use
Non-thermal effects need to be considered for workplace assessment
Thermal effects need to be considered for workplace assessment
Data is based on maximum power source capability (valid unless firmware/hardware is changed)
Data is based on worst case setting/program (only valid until setting options/welding programs are changed)
Data is based on multiple settings/programs (only valid until setting options/welding programs are changed)
Occupational exposure is below the Exposure Limit Values (ELVs)
for health effects at the standardized configurations
Occupational exposure is below the Exposure Limit Values (ELVs)
for sensory effects at the standardized configurations
Occupational exposure is below the Action Levels (ALs) at the
standardized configurations
EMF Data for Non-thermal Effects
Exposure Indices (EIs) and distances to welding circuit (for each operation mode, as applicable)
Standardized distance
ELV EI @ standardized distance
Required minimum distance
Distance where all occupational ELV Exposure Indices fall below 0.20 (20%)
Distance where all general public ELV Exposure Indices fall below 1.00 (100%)
Tested by:
Tony Samimi`
275641-C
Product
Directive 2014/35/EU
Directive 2013/35/EU, Recommendation 1999/519/EC
IEC 62822-1:2016, IEC 62822-2:2016
for occupational use
Head
Sensory
Effects
10 cm
0.16
1 cm
Date tested:
Stock Number
907366002
907366004
907161012
907431002
907420003
907730001
907731001
for use by laymen
(if NO, specific required minimum distances apply)
n.a
(if applicable and NO, specific measures are needed)
n.a
(if applicable and NO, specific signage is needed)
Health
Trunk
Effects
10 cm
10 cm
0.12
0.19
1 cm
1 cm
2016-03-03
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Limb (hand)
Limb (thigh)
3 cm
3 cm
0.11
0.24
1 cm
1 cm
9 cm
185 cm