A31Tp1 Signal Check - HP 8340B Manual

Hide thumbs Also See for 8340B:
Table of Contents

Advertisement

A31TP1 SIGNAL
CHECK
Test Setup
ON
THE
DUT:
The DUT
should
still
be
set to
a
CW
frequency of
4530 MHz
with
its
10
MHz REF
connected to
the
spectrum analyzer's
FREQ REFERENCE
input.
Connect the HP
1121A active probe to A31TP1.
ON
THE SPECTRUM ANALYZER:
As shown
in
the figures on the following page.
Proper Waveform
Parameters
As
shown
in
views
A
and
B
on the following page, and within the following parameters:
Frequency
=
3.333333 MHz
B-34
M/N
Loop Assembly-Level Troubleshooting