Cleaning and/or changing the filters:
1. Remove the two grilles from the ceiling assembly by
pulling the tabs on the grilles.
2. Remove and clean or replace the two filters.
3. Re-install the filters and grilles in the ceiling
assembly as shown in Figure 2.
4. If the vehicle is equipped with a flush mount ceiling
assembly, remove the four return air grille screws.
Remove the filter from the grille and either clean or
exchange with new filters.
NOTE: If replacement filters are necessary, the
filters can be purchased from most Airxcel, Inc.
Authorized Service Centers. It is recommended that
spare filters be carried with the RV at all times to
replace worn, torn or deteriorated filters.
II. Service Person
A. Electrical
inspection should be performed only by
qualified service personnel. Contact your
nearest Airxcel, Inc. Service Center if electrical
problems should arise.
B. Check points – Failure to start or cool the air
are sometimes problems with air conditioner
units. The Coleman-Mach RV Air Conditioner
is designed to operate on 230-240 volt, 50 Hz
electrical power. If the compressor on the air
conditioner fails to start, check with your
Airxcel, Inc. Service Center to determine that
the proper wire size is connected to the unit,
the proper circuit breakers are installed as
protection devices on the electrical circuit and
the proper sized extension cord is being used
for the distance covered from the utility outlet
to the RV.
If the air conditioner continues to trip off the circuit
breakers, have an electrician check the starting
amperage and the running amperage on the unit. If the
circuit breaker continues to trip off and the electrical
consumption is found to be normal, it will require the
replacement of the faulty circuit breaker.
Figure 2
All
electrical
work
If all electrical power to the air conditioner is normal but
neither the fan or the compressor will operate, the
connector plug located behind the ceiling assembly
control box should be checked to determine whether it
is faulty.
On the heating-cooling air conditioner models, if all
electrical power to the unit is normal and the fan runs
but you never get any heated air, even after
momentarily removing power and waiting ten (10)
minutes per item (iv Heat Operation) above, then the
electrical plug to the heating unit should be checked for
a secure connection. If this does not correct the
malfunction, the heating thermostat or limit switch may
be faulty.
Mechanical Integrity – The air conditioner should be
inspected periodically to be sure that the bolts which
and/or
secure the unit to the roof are tight and in good shape.
Also, an examination of the plastic shroud covering the
air conditioner on the top of the roof should be made
periodically. Be sure the four mounting screws and
washers are snug and holding the shroud to the air
conditioner. Also, examine the shroud to be sure it is
not developing cracks or has suffered damage from
impact.
For Full WARRANTY Terms and conditions on
products purchased in Australia or New Zealand,
please
www.coastrv.com.nz
For products purchased outside of the US, Australia or
New Zealand, please contact your AIRXCEL, INC.
distributor.
The
LIMTED
available on the AIRXCEL, INC. website, Airxcel.com
only applies to domestic U.S. products of AIRXCEL,
INC.
10
X. WARRANTY
visit
www.coastrv.com.au

WARRANTY